E-
31
ENGLISH
P
REPARING THE
I
NSTALLATION
Piping length and the height.
A-unit
B-unit
C-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
1/4
"
GAS
1/2
"
3/8
"
3/8
"
MAX. piping length
A
15 m (49ft. 3in)
15 m (49ft. 3in)
15 m (49ft. 3in)
MAX. height
B
7 m (23ft)
7 m (23ft)
7 m (23ft)
A
B
INDOOR UNIT
OUTDOOR UNIT
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
j Les dessins et les conceptions sont
soumis changer selon le %
A
B
160 mm
(6 inch)
or more
25 mm (1 inch)
or more
◗
27,000Btu/h
100 mm
(4 inch)
or more
100 mm
(4 inch)
minimum
600 mm
(24 inch)
minimum
600 mm (24 inch)
minimum
100 mm
(4 inch)
minimum
A-unit
13,000 Btu/h
B-unit
7,000 Btu/h
C-unit
7,000 Btu/h
Circuit breaker
(20A)
Main power switch
B
(7 m (23ft) maximum)
A
(15 m (49ft. 3in)
maximum)
AM27B1C07
AM27B1C13
UM27B1C3
1,208-230~,60
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
Summary of Contents for AM18B1C09
Page 26: ...E 26 INSTALLATION MANUAL...