
36
English
Installation Procedure
Installation Pr
oc
edur
e
3
Check whether the option values that you have set are
correct by pressing the
(Mode) button repeatedly
[SEG2, SEG3]
[SEG11 , SEG12 ]
[SEG21 , SEG22]
[SEG4, SEG5]
[SEG14 , SEG15 ]
[SEG23, SEG24]
[SEG6, SEG8]
[SEG16 , SEG17 ]
[SEG9, SEG10 ]
[SEG18 , SEG20]
4
Save the option values into the indoor unit:
Point the remote control to the remote control sensor
on the indoor unit and then press the
(Power)
button on the remote control twice. Make sure that
this command is received by the indoor unit. When it is
successfully received, you can hear a short sound from
the indoor unit. If the command is not received, press
the
(Power) button again.
5
Check whether the air conditioner operates in
accordance with the option values you have set:
a
Reset the indoor unit by disconnecting and then
reconnecting the power cable of the indoor unit or
by pressing the RESET button on the outdoor unit.
b
Remove the batteries from the remote control,
insert them again, and then press the
(Power)
button on the remote control.
Setting the indoor unit addresses (MAIN/RMC/MCU)
1
Make sure that the power is supplied to the indoor
unit.
࡛
If the indoor unit is not plugged in, it must include a
power supply.
2
Make sure that the panel or display is connected to the
indoor unit so that it can receive options.
Indoor unit
3
Set an address (MAIN/RMC/MCU port) for each indoor
unit using the remote control, according to your air
conditioning system plan.
࡛
The indoor unit addresses (MAIN/RMC/MCU port)
are set to 0A0000-100000-200000-300000 by
default.
NOTE
࡛
Also set the MCU and Indoor units address by using
Add-on
९
Change address on S-NET Pro 2.
(For more information, see the S-NET Pro 2 Help.)
࡛
From SEG13 to SEG18 is for setting MCU address.
ࣞ đAƸ͔ͱʒʪ̷ϑϩ˵ɇϩʀɇ͝ϑʪϩɇʒʒθʪϑϑࡤđAƸࣛƊ७ĘkçߤĘࡥ
MCU-S4NEK3N, MCU-S1NEK1N
Option No. for an indoor unit address: 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
Function
Page
Mode
Setting main
address
100-digit of an
indoor unit address
10-digit of an
indoor unit address
The single digit of
an indoor unit
Indication
and details
Indication Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details
0
A
0
No main
address
0 to 9
10-digit
0 to 9
A single
digit
0 to 3
A single
digit
1
Main
address
setting
mode