Install your appliance on a level and hard floor that can support its weight.

Failing to do so may result in abnormal vibrations, noise, or problems with the product.

 

Install the drain hose properly so that water is drained correctly.

Failing to do so may result in water overflowing and property damage. Avoid 
adding drain to waste pipes as odours may arise in the future.

 

The product shall be stored in a room with no ignition sources 
(e.g. open flames, gas appliance, electric heater, etc.).

Note that the refrigerant has no odour.

 

When installing the outdoor unit, make sure to connect the drain hose so that 
draining is performed correctly.

The water generated during the heating operation in the outdoor unit may 
overflow and result in property damage. 
In particular, in winter, if a block of ice falls, it may result in injury, death or 
property damage.

 

Do not install the product in a place where thermo-hygrostat is needed 
(such as server room, machinery room, computer room, etc.)

Those places do not provide guaranteed operation condition of the product 
therefore performance can be poor in these places.

FOR POWER SUPPLY

  WARNING

 

When the circuit breaker is damaged, contact your nearest service centre.

 

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not 
hook the power line over a metal object, place a heavy object on the power line, insert the 
power line between objects, or push the power line into the space behind the appliance.

This may result in electric shock or fire.

  CAUTION

 

When not using the air conditioner for a long period of time or during a thunder/

lightning storm, cut the power at the circuit breaker.

Failing to do so may result in electric shock or fire.

Summary of Contents for AJ TN1DKG Series

Page 1: ...Airconditioner Usermanual AJ TN1DKG Thank you for purchasing this Samsung air conditioner Before operating this unit please read this user manual carefully and retain it for future reference...

Page 2: ...ther household waste at the end of theirworking life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste...

Page 3: ...contact centre or find help and information online at www samsung com WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that m...

Page 4: ...t in electric shock orfire Fixthe outdoorunitfirmlysothatthe electric part ofthe outdoorunit is not exposed Failing to do so may result in electric shock orfire Do not installthis appliance neara heat...

Page 5: ...low and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage Do not installthe product in a placewherethermo hygrostat is needed s...

Page 6: ...ne Do not use a ventilating fan A spark may result in an explosion orfire To reinstallthe airconditioner please contactyournearest service centre Failing to do so may result in problems with the produ...

Page 7: ...t injure themselves by inserting theirfingers into the product Do not strike orpullthe airconditionerwith excessiveforce This may result in fire injury orproblems with the product Do not place an obje...

Page 8: ...ration ventilatethe room and consultyourdealerimmediatelyforrecharging refrigerant The refrigerant is not harmful However if it comes in contactwithfire it may generate harmful gases andthere is risk...

Page 9: ...iods oftime This may result in harm to humans animals orplants This appliance is not intendedforuse bypersons including children with reduced physical sensoryormental capabilities orlack of experience...

Page 10: ...fire CAUTION Take carewhen cleaningthe surface ofthe heat exchangerofthe outdoorunit since it has sharp edges To avoid cutting yourfingers wearthick cotton gloves when cleaning it This should be done...

Page 11: ...he panel type 02 01 04 05 03 01 Display 02 Remote control sensor 03 Airflow blade 04 Wind Free panel You can use the Wind Free Cooling function when the Cool Dry orFan mode is running Referto the remo...

Page 12: ...ess Heat mode Dry mode A A CAUTION If you use the air conditioner at a relative humidity above 80 it may cause a formation of condensation and a leakage of water on the floor The rated heating capacit...

Page 13: ...es Do not attach any stickers on the surfaces because this may cause damage When you clean the heat exchanger on the indoor unit you need to disassemble the indoor unit Therefore you must contact the...

Page 14: ...e to hold the grille with a hand to prevent dropping from the opening of the front grille NOTE When removing the grill completely unhook the safety hooks on both sides of the grill 1 Detaching the air...

Page 15: ...dries in a humid area it may produce offensive odours Clean it again and dry it in a well ventilated area The cleaning period may differ depending on the usage and environmental conditions so clean t...

Page 16: ...embling the air filter be sure to reset the filter cleaning reminder as follows Indoor unit with the wired remote control Press the FilterReset button Indoor unit with the wireless remote control Pres...

Page 17: ...d Replace the remote control batteries At least once a year Outdoor unit Clean the heat exchanger on the outside of the unit Once every 4 months Required Clean the heat exchanger on the inside of the...

Page 18: ...The temperature does not change Check whether the Fan mode is running In the Fan mode the air conditioner controls the set temperature automatically and you cannot change the set temperature Warm air...

Page 19: ...ool mode cool air does not come out if the set temperature is higher than the current temperature Remote control Press the Temperature button repeatedly until the set temperature minimum 18 C is set t...

Page 20: ...a smoky area or if there is a smell entering from outside ventilate the room properly If both indoor temperature and indoor humidity are high operate the air conditioner in the Clean or Fan mode for1...

Page 21: ...kage at least once every12 months according to regulation No 517 2014 This activity must be covered by qualified personnel only In the case of the situation above the installer or authorized person wi...

Page 22: ...support German www samsung com ch_fr support French HUNGARY 0680SAMSUNG 0680 726 7864 www samsung com hu support CZECH 800 SAMSUNG 800 726786 www samsung com cz support SLOVAKIA 0800 SAMSUNG 0800 726...

Reviews: