The installation of this appliance must be performed by a qualified 
technician or service company.

•  Failing to do so may result in electric shock, fire, explosion, problems with 

the product, or injury and may also void warranty on the installed product.

 

Install a Isolation Switch next to the Fan Coil Unit (but not on the panels of 
the Fan Coil Unit)and circuit breaker dedicated to the fan coil unit.

•  Failing to do so may result in electric shock or fire.

 

Do not install this appliance near a heater, inflammable material. Do 
not install this appliance in a humid, oily or dusty location, in a location 
exposed to direct sunlight and water (rain drops). Do not install this 
appliance in a location where gas may leak.

•  This may result in electric shock or fire.

 

This appliance must be properly grounded. Do not ground the appliance to 
a gas pipe, plastic water pipe, or telephone line.

•  Failure to do so may result in electric shock, fire, an explosion, or other 

problems with the product.

•  Never plug the power cord into a socket that is not grounded correctly 

and make sure that it is in accordance with local and national codes.

  CAUTION

 

Install your appliance on a level and hard floor that can support its weight.

•  Failing to do so may result in abnormal vibrations, noise, or problems with 

the product.

 

When installing the product, make sure to install the draining hose 
properly, so that water is drained correctly.

•  Failing to do so may result in water overflowing and property damage.

Summary of Contents for AG026MN1DEH/EU

Page 1: ...il Unit Usermanual ००००ĘߢUk ० ࢥ ००००ĘߥUç ० ࢥ ००००Ęߥťç ० Thank you for purchasing this Samsung fan coil unit Before operating this unit please read this user manual carefully and retain it for future reference ...

Page 2: ... theirworking life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailerwhere they purchased this product or their local government office for details of where and how they...

Page 3: ...nsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage Follow directions Do NOT attempt Make sure the machine is grounded to prevent electric shock Cut off the power supply Do NOT disassemble FOR INSTALLATION WARNING Use the powerline with the powerspecifications of the product orhigher and ...

Page 4: ... direct sunlight and water rain drops Do not install this appliance in a location where gas may leak This may result in electric shock or fire This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic waterpipe ortelephone line Failure to do so may result in electric shock fire an explosion or other problems with the product Never plug the power cord into a socket ...

Page 5: ...r first and then stop the fan coil unit If the heat source device e g chillerorboiler will not be used formore than fourhours when in Cool mode stop watercirculation If it is impossible to stop watercirculation decrease the fan speed If cold water runs when the fan of the fan coil unit is off condensation may occur on the fan coil unit components such as the main unit motor or grille and affect th...

Page 6: ...in electric shock or fire CAUTION When not using the fan coil unit fora long period of time orduring a thunder lightning storm cut the powerat the circuit breaker Failing to do so may result in electric shock or fire Cut off the powerto the valve before cutting off the powerto the product Power is consumed if the power supply is connected Install an electric two way valve at the inlet of the fan c...

Page 7: ...oil unit please contact yournearest service centre Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged Especially when you wish to install the product in an unusual location such as in ...

Page 8: ...o the airinlet outlet of the fan coil unit Take special care that children do not injure themselves by inserting their fingers into the product Do not strike orpull the fan coil unit with excessive force This may result in fire injury or problems with the product Do not use this fan coil unit forlong periods of time in badlyventilated locations ornearinfirm people Since this may be dangerous due t...

Page 9: ...n electric shock Do not sprayvolatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the waterfrom the fan coil unit The water may be harmful to humans Do not apply a strong impact to the remote controllerand do not disassemble the remote controller Do not touch th...

Page 10: ...se of the appliance in a safe way and understand the hazards involved Children shall not playwith the appliance Cleaning and user maintenance shall not be made by children without supervision FOR CLEANING WARNING Do not clean the appliance by spraying waterdirectly onto it Do not use benzene thinner alcohol oracetone to clean the appliance This may result in discoloration deformation damage electr...

Page 11: ...Panel 04 Airintake Front grille inside Airfilter NOTE Refer to the remote control user manual for details on how to use the product The power button will not work Use the remote control to turn on or off the product When operating a Fan Coil Unit including Fan mode the S Plasma Ion function may not operate automatically In this case turn on the Purity function with your remote control to activate ...

Page 12: ...ndicator Filter reset indicator Remote control sensor 02 Airflow blade 03 Airintake Front grille inside Airfilter NOTE Each of the air flow blades can be controlled separately Refer to the remote control user manual for details on how to use the product Note 1 The power button will not work Use the remote control to turn on or off the product Note 2 The removing frost indicator does not works ...

Page 13: ...ndications that appear on the fan coil unit display For the MR EH00 wired remote control which is designed generally for any fan coil unit the air flow direction is not shown on the remote control display Control the air flow direction with checking it on the fan coil unit display For information on how to operate the product see the user manual for the remote control By using the AR KH00E wireles...

Page 14: ...conditions for an extended period of time à ͱΧʪθɇϩ ϩ ʪ ɇ ʀͱ Ї ϩ Ї ʒʪθ ʀͱ ʒ ϩ ͱ ϑ и ϩ иɇϩʪθ ϩʪ ΧʪθɇϩЇθʪ ͱЭʪθ ߧߦঐࡡ Χθͱϩʪʀϩ Эʪ control shutdown mode may activate to protect the product If using the product in a location with temperature and humidity outside the standard operating range the protective system activates and the product may not operate Use the product under conditions with temperature an...

Page 15: ...r dry cloth when needed Wipe off dirt of odd shaped areas by using a soft brush CAUTION Do not use alkaline detergent sulphuric acid hydrochloric acid or organic solvents such as thinner kerosene and acetone to clean the surfaces Do not attach any stickers on the surfaces because this may cause damage When you clean the heat exchanger on the fan coil unit you need to disassemble the fan coil unit ...

Page 16: ...xiliary power switch MCCB ELB Be sure to hold the grille with a hand to prevent dropping from the opening of the front grille 1 WAY 1 Detaching and replacing the air filter PC1NUSMAN PUSH Press the Push signs on the front panel then open the grille Grab the handle of the air filter and lift it upward while pushing the handle slightly Pull out the air filter from the fan coil unit ...

Page 17: ...ing and Maintenance PC1BWSMAN Insert your hand into the front grille and pull out the front grille to open it Press the Push signs on the air filter Grab the handle of the air filterwith your hand Pull out the air filter from the fan coil unit ...

Page 18: ...e from the filter if it is very dirty If this is the case immerse the filter in warm waterwith a neutral detergent for about 30 minutes and then rinse it thoroughly Lean the filter against a wall to maximise air contact for drying in the shade with no direct sunlight for at least 12 hours If the air filter dries in a humid area it may produce offensive odours Clean it again and dry it in a well ve...

Page 19: ...ing and reassembling the air filter be sure to reset the filter cleaning reminder as follows Fan coil unit with the wired remote control Press the Filter Reset button Fan coil unit with the wireless remote control Press the Settings ɵЇϩϩͱ २ or २ Filter Reset 9 २ Χθʪϑϑ ϩ ʪ SET button NOTE Be sure to reset the filter cleaning reminder every time you clean the air filter although the filter reset ind...

Page 20: ...lter Open the air flow blades on both sides of the front grille then open the front grille by pushing the two push buttons NOTE The push buttons are located on both sides of the front grill with the Samsung logo You can find the buttons by opening the air flow blades with your hands Pull out the air filter from the fan coil unit ...

Page 21: ...lter if it is very dirty If this is the case immerse the filter in warm waterwith a neutral detergent for about 30 minutes and then rinse it thoroughly Lean the filter against a wall to maximise air contact for drying in the shade with no direct sunlight for at least 12 hours If the air filter dries in a humid area it may produce offensive odours Clean it again and dry it in a well ventilated area...

Page 22: ...remote control Press the Filter Reset button Fan coil unit with the wireless remote control Press the Settings ɵЇϩϩͱ २ or २ Filter Reset 9 २ Χθʪϑϑ ϩ ʪ SET button NOTE The filter reset indicator blinks when the air filter should be cleaned If the angle of the air flow blade is changed by opening the front grille for installation or maintenance of the fan coil unit be sure to turn off and then on th...

Page 23: ... the fan coil unit body Unhook the two hook wires of the grille inlet from the two wire hooks on the fan coil unit body Pull out the air filter from the grille inlet CAUTION For cleaning and maintenance be sure to turn off the circuit breaker NOTE When the next filter cleaning time arrives after1000 hours of operation the fan coil unit display appears in yellow green ...

Page 24: ...o heavy then rinse it with running water NOTE Clean the air filter once every two weeks Spray water or use a vacuum cleaner to remove dust After removing dust dry the air filter completely Avoid direct sunlight Failure to do so may deform the air filter NOTE If the air filter dries in a humid area it may produce offensive odours Clean it again and dry it in a well ventilated area ...

Page 25: ...so that it is assembled firmly in place Make sure that the grill inlet is firmly fixed to the fan coil unit body 4 Resetting the air filter After cleaning and reassembling the air filter reset the filter cleaning reminder as follows AR KH00E remote control Select Filter Reset MR EH00 remote control Hold down the Filter Reset button for two seconds NOTE If you try to assemble the air filter upside ...

Page 26: ...tenance item Interval Requires qualified technicians Clean the air filter At least once a month Clean the condensate drain pan Once a year Required Clean up the heat exchange Once a year Required Clean the condensate drain pipe Once every 4 months Required Replace the remote control batteries At least once a year ...

Page 27: ...e MR EH00 remote control Press the Temperature button repeatedly until the set temperature minimum 18 C is set to lowerthan the current temperature AR KH00E remote control Press the Temperature button on the remote control Then rotate the Wheel until the set temperature minimum 18 C is set to lowerthan the current temperature In the Heat mode warm airdoes not come out if the set temperature is low...

Page 28: ...blades are fixed upwards in summeroff state but the blades are fixed downwards if there is no cool air The wireless remote control does not operate Check whetherthe batteries are discharged Replace the batteries with new ones Make sure that nothing is blocking the remote control sensor Check whether any strong lighting sources are near the fan coil unit Strong light which comes from fluorescent bu...

Page 29: ...t If the fan coil unit display is still blinking contact a service centre Condensation forms on the product If using Cool mode with doors open humid airtouches the airoutlet and condensation may form on the panel and heater Close the doors The fan coil unit makes strange noises The drain pump inside the product may make operation noises immediately afterthe Power button is pressed This noise is a ...

Page 30: ... EU 10 5kg 970 135 410 AG032MN1DEH EU 10 5kg 970 135 410 AG042MN1DEH EU 14 0kg 1 200 138 450 AG060MN4DKH EU 15 5kg 840 204 840 AG072MN4DKH EU 15 5kg 840 204 840 AG090MN4DKH EU 18 0kg 840 246 840 AG105MN4DKH EU 18 0kg 840 246 840 AG060MN4PKH EU 21 0kg 947 281 947 AG072MN4PKH EU 25 0kg 947 365 947 AG090MN4PKH EU 25 0kg 947 365 947 AG105MN4PKH EU 25 0kg 947 365 947 ...

Page 31: ...Cleaning and Maintenance 31 English Cleaning and Maintenance MEMO ...

Page 32: ...t AUSTRIA 0800 SAMSUNG 0800 7267864 Only for Premium HA 0800 366661 Only for Dealers 0810 112233 www samsung com at support SWITZERLAND 0800 726 78 64 0800 SAMSUNG www samsung com ch support German www samsung com ch_fr support French CZECH 800 SAMSUNG 800 726786 www samsung com cz support SLOVAKIA 0800 SAMSUNG 0800 726 786 www samsung com sk support CROATIA 072 726 786 www samsung com hr support ...