ENGLISH-71
03
INST
ALL
ATION
Optional : Extending the power cable
1 . Prepare the following tools .
Tools
Spec
Shape
Crimping pliers
MH-14
Connection sleeve (mm)
20xØ6 .5 (HxOD)
Insulation tape
Width 19 mm
Contraction tube (mm)
70xØ8 .0 (LxOD)
2 . As shown in the figure, peel off the shields from the rubber and wire of the power cable .
•
Peel off 20 mm of cable shields from the pre-installed tube .
• For information about the power cable specifications for indoor and outdoor units, refer to the installation
manual .
• After peeling off cable wires from the pre-installed tube, insert a contraction tube .
• If cable wires are connected without using connecting sleeves, their contact area becomes reduced, or corrosion
develops on the outer surfaces of the wires (copper wires) over a long time . This may cause an increase of
resistance (reduction of passing current) and consequently may result in a fire .
CAUTION
20
20
20
60
120
180
Power cable
20
20
20
60
120
180
Pre-installed
tube for the
power cable
(Unit: mm)
3 . Insert both sides of core wire of the power cable into the connection sleeve .
•
Method 1: Push the core wire into the sleeve from both sides .
•
Method 2: Twist the wire cores together and push it into the sleeve .
Method 1
Method 2
Connection sleeve
Connection sleeve
4 . Using a crimping tool, compress the two points and flip it over and compress another two points in the same location .
•
The compression dimension should be 8 .0 .
Compression
dimension