Samsung Electronics
3-16
No
Parts
Procedure
Remark
3
ASS'Y Control Out
1) Detach several connectors from the
ASS'Y Control Out.
2) Detach several connectors from the PCB
of ASS'Y Control Out.
3) Pull up the ASS'Y Control Out.
4
Heat Exchanger
1) Release the refrigerant at first.
2) Loosen fixing screw on both sides.
3) Disassemble the pipes in both inlet and
outlet with welding torch.
4) Detach the Heat Exchanger.
5) Loosen 4 bolts fixed to assemble Valve
Service with Bracket Valve like the picture
on the right side.