Wire remote controller display
E122
Symptom
Error of EVA-IN,EVA-OUT sensor in the indoor unit(Open/Short)
Failure
Short or leakage of the EVA sensor
4-7-2 Eva in and out sensor (open/short)
Yes
No
No
In this case, is the resistance
value out of range in the temperature
table on the right?
Yes
Is indoor temperature
sensor disconnected from the
connector in PCB?(CN413)
Restart the system after replacing the PCB
Restart the system after connecting
to the PCB connector
EVA sensor failure (replace)
Remove the indoor temperature sensor
connector from the PCB and measure the
resistance between two terminals
Current tem-
perature (°C)
Resistance
(kΩ)
70
2.229
60
3.021
50
4.160
40
5.828
30
8.313
20
12.09
10
17.95
0
27.27
-10
42.42
-20
67.72
-30
111.2
<Temperature sensor
resistance value>