background image

Cl

eaning and Maint

enanc

e

13

English

Cl

eaning and Maint

enanc

e

Before cleaning the indoor unit, be sure to turn off the auxiliary power switch.

Cleaning and Maintaining

Cleaning the indoor unit exterior 

Wipe the surface of the unit with a slightly wet 

or dry cloth when needed. Wipe off dirt of odd-

shaped areas by using a soft brush.

  CAUTION

• 

Do not use alkaline detergent, sulphuric 

acid, hydrochloric acid, or organic solvents 

(such as thinner, kerosene, and acetone) to 

clean the surfaces.

• 

Do not attach any stickers on the surfaces 

because this may cause damage.

• 

When you clean the heat exchanger on the 

indoor unit, you need to disassemble the 

indoor unit. Therefore, you must contact the 

local service center for help.

Cleaning the outdoor unit heat exchanger

Spray water to clean the dust.

  CAUTION

• 

The heat exchanger of the outdoor unit has 

sharp edges. Take care when cleaning its 

surface.

  NOTE

• 

Cleaning the heat exchanger may cause 

damage to the surface, only clean with 

water. 

• 

Maintenance to the outdoor unit requires 

service by qualified technicians. 

Cleaning and Maintenance

Summary of Contents for AC TNNDKG Series

Page 1: ...rconditioner Usermanual AC TNNDKG Thank you for purchasing this Samsung air conditioner Before operating this unit please read this user manual carefully and retain it for future reference DB68 08480A 00 ...

Page 2: ...ic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of theirworking life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either t...

Page 3: ... unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage Follow directions Do NOT attempt Make sure the machine is grounded to prevent electric shock Cut off the power supply Do NOT disassemble FOR INSTALLATION WARNING Use the powerline with the powerspecifications of the product orhigher an...

Page 4: ...terial Do not install this appliance in a humid oily ordusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak This may result in electric shock or fire Neverinstall the outdoorunit in a location such as on a high external wall where it could fall If the outdoor unit falls it may result in injury death or property ...

Page 5: ...hat draining is performed correctly The water generated during the heating operation in the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage FOR POWER SUPPLY WARNING When the circuit breakeris damaged contact yournearest service centre Do not pull orexcessively bend the powerline Do not twist or...

Page 6: ...use a ventilating fan A spark may result in an explosion or fire To reinstall the airconditioner please contact yournearest service centre Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be ch...

Page 7: ...injure themselves by inserting their fingers into the product Do not strike orpull the airconditionerwith excessive force This may result in fire injury or problems with the product Do not place an object nearthe outdoorunit that allows children to climb onto the machine This may result in children seriously injuring themselves Do not use this airconditionerforlong periods of time in badlyventilat...

Page 8: ... standard forenergy efficiency When the airconditionerdoes not operate properly forcooling orheating there is a possibility of refrigerant leakage If any leakage stop operation ventilate the room and consult yourdealerimmediately forrecharging refrigerant The refrigerant is not harmful However if it comes in contact with fire it may generate harmful gases and there is risk of fire During transport...

Page 9: ...Do not point the airdirection to the fireplace orheater Do not use this airconditionerto preserve precision equipment food animals plants orcosmetics orforany otherunusual purposes This may result in property damage Avoid directly exposing humans animals orplants to the airflow from the airconditionerforlong periods of time This may result in harm to humans animals or plants This appliance is not ...

Page 10: ...ON Take care when cleaning the surface of the heat exchangerof the outdoor unit since it has sharp edges To avoid cutting your fingers wear thick cotton gloves when cleaning it This should be done by a qualified technician please contact your installer or service centre Do not clean the inside of the airconditionerbyyourself For cleaning inside the appliance contact your nearest service centre Whe...

Page 11: ...e IndoorUnit Overview 02 04 03 01 01 Display 02 Airflow blade Airoutlet inside Wind Free panel You can use the Wind Free Cooling function when the Cool Dry orFan mode is running 03 Airintake 04 Airfilter underthe grille Indication Function On Off operation indicator Defrost operation indicator Timer indicator Filter cleaning indicator Remote control sensor ...

Page 12: ... Cool mode 15 C to 50 C 18 C to 32 C 80 or less Heat mode 20 C to 24 C 30 C or less Dry mode 15 C to 50 C 18 C to 32 C 80 or less CAUTION If you use the air conditioner at a relative humidity above 80 it may cause a formation of condensation and a leakage of water on the floor The rated heating capacity is based on an outdoor temperature of 7 C If the outdoor temperature goes down below 0 C heatin...

Page 13: ...nts such as thinner kerosene and acetone to clean the surfaces Do not attach any stickers on the surfaces because this may cause damage When you clean the heat exchanger on the indoor unit you need to disassemble the indoor unit Therefore you must contact the local service center for help Cleaning the outdoorunit heat exchanger Spraywaterto clean the dust CAUTION The heat exchanger of the outdoor ...

Page 14: ...ll out the air filter from the indoor unit 2 Cleaning the air filter Clean the air filterwith a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area CAUTION Do not scrub the air filterwith a brush or other cleaning utensil This may damage the filter NOTE If the air filter dries in a humid area it may produce offensive odours Clean it ag...

Page 15: ...ol Press the Filter Reset button Indoor unit with the wireless remote control Press the Options button or Filter Reset Blinking press the SET button NOTE The filter reset indicator blinks when the air filter should be cleaned If the angle of the air flow blade is changed by opening the front grille for installation or maintenance of the indoor unit be sure to turn off and then on the auxiliary swi...

Page 16: ...nce every 4 months Required Replace the remote control batteries At least once a year Outdoor unit Clean the heat exchanger on the outside of the unit Once every 4 months Required Clean the heat exchanger on the inside of the unit Once a year Required Clean the electric components with jets of air Once a year Required Verify that all the electric components are firmly tightened Once a year Require...

Page 17: ... Make sure that auxiliary power switch MCCB ELB is installed in the distribution box inside the building If the air conditioner is turned off by the Timed off function turn on the air conditioner again by pressing the Power button The temperature does not change Check whether the Fan mode is running In the Fan mode the air conditioner controls the set temperature automatically and you cannot chang...

Page 18: ... cooler air Operate the air conditionerwith a electric fan to save energy and enhance the cooling efficiency The air is not cool or warm enough In the Cool mode cool air does not come out if the set temperature is higher than the current temperature Remote control Press the Temperature button repeatedly until the set temperature minimum 18 C is set to lower than the current temperature In the Heat...

Page 19: ... or if there is a smell entering from outside ventilate the room properly If both indoor temperature and indoor humidity are high operate the air conditioner in the Clean or Fan mode for1 to 2 hours If the air conditioner has not been operated for an extended period of time clean the indoor unit and then operate the air conditioner in the Fan mode for 3 to 4 hours to dry the inside of the indoor u...

Page 20: ...COUNTRY CALL OR VISIT US ONLINE AT AUSTRALIA 1300 362 603 Other 1300 425 299 HHP www samsung com au support QUESTIONS OR COMMENTS This appliance is filled with R 32 ...

Reviews: