Operation Features
Operating temperature and humidity
When using the air conditioner follow the operating temperature and humidity ranges.
Model
Mode
Outdoor
temperature
Indoor
temperature
Indoor humidity
AC026RNNDKG
AC035RNNDKG
Cool mode
-15°C to 46°C
18°C to 32°C
80% or less
Heat mode
-20°C to 24°C
30°C or less
-
Dry mode
-15°C to 46°C
18°C to 32°C
80% or less
AC052RNNDKG
AC071RNNDKG
Cool mode
-15°C to 50°C
18°C to 32°C
80% or less
Heat mode
-20°C to 24°C
30°C or less
-
Dry mode
-15°C to 50°C
18°C to 32°C
80% or less
CAUTION
•
If you use the air conditioner at a relative humidity above 80%, it may cause a formation of
condensation and a leakage of water on the floor.
•
The rated heating capacity is based on an outdoor temperature of 7°C. If the outdoor temperature
goes down below 0°C, heating efficiencies may decrease depending on the temperature
conditions.
•
If the indoor unit is out of the operating temperature and humidity range, the safery device may
operate and the air conditioner may stops.