background image

8

Operating The ZM Series

Setting up the ZM series

Setting up your ZM Series is a simple procedure, which takes 

only a few minutes:

 Remove all packing materials (save them in case of need 

for future service) and decide where the amplifier is to be 

physically placed—it can be used table-top or mounted in a 

standard 19” rack (like the SRK equipment racks from Samson), 

requiring only two rack spaces. 

Install the rack ears by aligning them to the side of the unit, 

flush to the front and install the supplied screws. Be careful 

not to cross thread the screws. Then, remove the feet to allow 

the unit to fit the 2 rack spaces.

When installed, make sure that both the front and rear panels 

are unobstructed and that there is good ventilation around 

the entire unit (we recommend the use of spacer panels, 

especially if multiple amplifiers are used in a rack.

Connecting the Speakers to the ZM Amplifier

Make the speaker connections, using the Euroblock output 

connectors on the rear panel.  It is never a good idea to power 

up any amplifier that is not connected to loudspeakers.  When 

operating using the 4-ohm output, any loudspeakers with 

a minimum impedance load of 4 ohms (that is, 4 ohms or 

greater) can be used. 

For 70-volt operation, connect the positive input of the 

speaker to the 70 Volt terminals and connect the negative 

input the COM (ground) terminal. 

The constant voltage output is set for either 70 or 100 Volts 

depending on the country, however if can be changed by re-

configuring the internal transformer wires. Locate the T10, T11, 

T12 and T13 terminals as per the diagram below.

Now follow the wiring chart below to select the required 

operating voltage for constant voltage output.

-

+

8Ω

8Ω

4Ω

-

+

-

+

OUTPUT

COM

Constant Voltage 100V/70V/25V

Lo-Z

OR

OUTPUT

COM

Constant Voltage 100V/70V/25V

Lo-Z

-

+

+

-

+

-

+

-

Matching
transformer

-

+

Summary of Contents for ZM125

Page 1: ...AX MIN MAX MIN MAX MIN MAX ALL ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 12dB 0 dB 12dB 12 0 12 125Hz 250Hz 500Hz 1kHz 8kHz 3 0 4 10 20 ON OFF MIN MAX 2kHz 4kHz SAMSON MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX...

Page 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Page 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Page 4: ...samsontech com Table of Contents Introduction 1 ZM Series Features 2 ZM Series Layout Front Panel 3 ZM Series Layout Rear Panel 4 Designing an Installation Plan 5 Operating The ZM Series 8 Operating...

Page 5: ...he ZM75 and ZM125 can be table top or mounted in a standard 19 inch equipment rack using the included rack mount ears The sleek black finish matches just about any d cor plus the steel chassis adds to...

Page 6: ...ce or pre recorded announcement to your telephone system A convenient telephone paging input on a Euroblock terminal allows you to interface your PBX system for handset paging 12dB 0 dB 12dB 12 0 12 1...

Page 7: ...6 LEVEL control knob The six control knobs are used to set the individual level of the input sources 7 MASTER control knob This control knob adjusts the overall system volume 12dB 0 dB 12dB 12 0 12 1...

Page 8: ...G C H G C H G C SW H LINK OUT PRE AMP OUT LINK IN AMP IN MAX VOLUME VOLUME MIN MAX MIN MAX INT EXT MUSIC ON HOLD CHIME TELE PAGING MIC 1 2 3 4 7 6 5 9 8 11 10 12 13 14 15 16 17 18 19 OUTPUT COM Const...

Page 9: ...connecting microphones with phantom power to operate condenser type mics The ZM series also has a special priority feature so when you speak on the microphone the music is automati cally muted You can...

Page 10: ...using an equipment rack such as one of the Samson SRK series To select a good location for your equipment rack you should consider several points including the proximity to each of the sound zones if...

Page 11: ...mplifiers have built in transformers on each channel that step up the output voltage and reduce the current allowing you to connect to a series of speakers with step down transformers over long cable...

Page 12: ...lly if multiple amplifiers are used in a rack Connecting the Speakers to the ZM Amplifier Make the speaker connections using the Euroblock output connectors on the rear panel It is never a good idea t...

Page 13: ...l If your mixer has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced two conductor connections can also be used but you ll get better signal quality and less...

Page 14: ...S com plus equalizer like the Samson D2500 digital equalizer or feedback management systems like the Samson D3500 Connect the PRE AMP OUT to the input of the signal processor Then connect the output o...

Page 15: ...eries constant voltage outputs are connected to two ceiling speakers in each of the Dining Rooms with their transformers set to a 12 watt tap The third constant voltage output powers two speakers in t...

Page 16: ...older Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no connection Tip signal Sleeve ground 2 3 1 Male XLR Hot 2 Cold 3 Common 1 End View Solder Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no c...

Page 17: ...PAY ATTENTION TO THE WARNING SYMBOL AND AVOID ELECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER Follow the guidelines below to select th...

Page 18: ...Ratio at rated power output Better than 90dB Crosstalk at all control maximum 70dB at 1kHz Rated Output Power at THD 0 36 60Watts 120Watts Total Harmonic Distortion THD at 1kHz rated power Less than 0...

Page 19: ...15 Block Diagram...

Page 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Reviews: