Samson S-convert Owner'S Manual Download Page 5

5

Operating the S convert

The basic procedure for setting up and using your S convert is simple and takes only a
few minutes. Remove all packing materials (save them in case of need for future service)
and check to make sure that you remove the supplied AC power adapter.

• 

Connect the output from the device you want to level match (like a consumer CD
player using standard RCA cables) to the S converts –10dBV, Left & Right RCA
inputs.

• 

Using standard XLR to XLR mic cables, connect the S convert’s +4dBu Left & Right
OUTPUTS to the professional DAT recorder balanced inputs.

• 

Set the -10 dBV LEVEL control to the detent position (12:00 o’clock).

• 

Set the +4 dBu LEVEL control to the detent position (12:00 o’clock).

Plug the S converts power adapter into a wall outlet and switch the unit on by press-
ing the power switch.

Apply a signal from the output of the CD, and monitor the input of the DAT recorder.

If necessary, you can use the –10 LEVEL control to fine tune the level sent out of the
S convert.

Using the LEVEL controls

Both the +4dBU and –10dBV inputs have a LEVEL control that you can use to slightly
adjust either of the inputs. The fact is, not all gear is calibrated to the same input and out-
put levels. There are plenty of great sounding devices whose input and output levels are all
over the board. S convert’s LEVEL controls can be tremendously useful in precisely
matching the signal of different gear, which will maximize signal to noise ratio and improve
the overall sound of your recordings or live performance. The LEVEL controls have cen-
ter detents so when placed in the detent (12:00 o’clock) position the unit is at unity gain
and the LEVEL control has no effect on the signal. Moving the LEVEL control to the left
will decrease the signal, and moving the LEVEL control to the right will increase the sig-
nal.

Summary of Contents for S-convert

Page 1: ...Line Level Converter Box S C l a s s S i g n a l P r o c e s s o r s...

Page 2: ...nvert Using the LEVEL controls 5 Typical Set up 6 Wiring Guide 7 Specifications 8 Copyright 2003 Samson Technologies Corp Printed January 2003 Samson Technologies Corp 575 Underhill Blvd P O Box 9031...

Page 3: ...on vert to calibrate your signals to an exact level And just because this unit is miniature don t be surprised with its great sound and reliability thanks to high quality components and solid build co...

Page 4: ...XLR balanced input for connecting right 4 dBu input signals 4 10 OUTPUT RIGHT RCA con nector outputs the right side 10 dBV signal 5 10 OUTPUT LEFT RCA connec tor outputs the left side 10 dBV signal C...

Page 5: ...pply a signal from the output of the CD and monitor the input of the DAT recorder If necessary you can use the 10 LEVEL control to fine tune the level sent out of the S convert Using the LEVEL control...

Page 6: ...iagram below shows a typical set up for a project recording studio using the S con vert to match the levels of a consumer CD player to the correct operating level of a profes sional DAT recorder 6 Ope...

Page 7: ...7 3 S convert Wiring Guide Wiring Guide There are several ways to interface the S convert depending on your exact set up Follow the cable diagrams below for connecting your gear...

Page 8: ...Level 110 dBu Maximum Ouput Level Bal 18 dBu Unbal 16 dBV Max Input Level Bal 22 dBu Unbal 20 dBV Input Impedance RCA 100k Ohm XLR 10k Ohm Output Impedance RCA 100 Ohm XLR 100 Ohm balanced Maximum Ga...