background image

10

Setting up your PS15, PB15, or PB15Pro is a simple procedure which takes only a few 

minutes:

 

1.   Remove all packing materials (save them in case of need for future service) and 

install the unit in a standard 19” rack. We recommend that the PB15 and PB15Pro 

be placed in the top slot so that its slide-out LED lamps can be used to illuminate 

the entire rack of equipment below. 

2.   Connect the PS15, PB15, or PB15Pro to any standard grounded AC outlet.  If you 

are using a PB15Pro, the front-panel voltmeter and ammeter will show you the 

incoming electrical voltage and current draw of connected equipment. 

3.   Connect the AC cables of your rack equipment to the rear-panel switched AC 

outlets, using the vertically mounted receptacles for external AC transformer 

power adapters. 

4.   Make sure all connected equipment is switched off, then press the front panel 

Outlets switch so that its status light is lit red.  This activates all rear panel 

switched outlets. 

5.   Turn on all connected equipment, one at a time.  If the total load exceeds 15 

amps, the front-panel circuit breaker will trip.  To reset it, unplug one or more 

devices, then press in the front panel circuit breaker. 

6.   You can also use the unswitched front panel convenience outlet for additional 

temporary power needs (such as connecting a guitar amplifier, soldering iron, 

etc.).  This outlet is fully operational whenever the PS15, PB15, or PB15Pro is 

plugged into an AC source, regardless of the position of the front panel Outlets 

switch.  The front panel circuit breaker affects this outlet as well as all rear-panel 

switched outlets. 

7.   (PB15 and PB15Pro only) - To illuminate the equipment in your rack, gently pull 

the front-panel slide-out cylinders out towards you. The lamps will switch on 

automatically .  You can also illuminate the back of your rack by connecting the 

included USB gooseneck LED light.

Setting Up and Using Your PowerStrip or PowerBrite 

Summary of Contents for Pro Rack-Mount Power Distribution PB15

Page 1: ...PS15 PB15 PB15PRO RACK MOUNT POWER DISTRIBUTION...

Page 2: ...cep tacles and at the point at which they exit from the unit 11 Unplug this unit during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified personnel Servicing...

Page 3: ...784 2201 www samsontech com Table of Contents Introduction 2 PowerBrite Features 3 PS15 Guided Tour Front Panel 4 PS15 Guided Tour Rear Panel 5 PB15 Guided Tour Front Panel 6 PB15 Guided Tour Rear Pa...

Page 4: ...low us to send you updated information about other Samson products in the future Also be sure to check out our website www samsontech com for complete information about our full product line With prop...

Page 5: ...iency and minimal noise Front panel re settable 15 amp circuit breaker protects all connected gear An independent dedicated switch with status light for powering the rear panel switched outlets In the...

Page 6: ...o reduce the load and gently press the circuit breaker in until you hear it click Note It may take a minute to cool before you can reset it 2 Vent Convection cooling is accomplished by the front panel...

Page 7: ...nt to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 2 on the previous page 3 Switched AC outlets vertical mount Similar to the AC outlets describe...

Page 8: ...fore you can reset it 2 Dimmer Use this to adjust the level of the LED light in the slide out Lamps 3 Lamps Contains the PB15 s 5 LED light Use the Dimmer control see 2 above to adjust the brightness...

Page 9: ...ets horizontal mount Connect external equipment to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 6 on the previous page 4 Switched AC outlets vert...

Page 10: ...in the electrical signal being received by the PowerBrite PB15Pro WARNING Severe voltage swings can cause damage to connected equipment If you see the voltmeter changing drastically or rapidly disconn...

Page 11: ...s horizontal mount Connect external equipment to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 8 on the previous page 4 Switched AC outlets vertic...

Page 12: ...el Outlets switch so that its status light is lit red This activates all rear panel switched outlets 5 Turn on all connected equipment one at a time If the total load exceeds 15 amps the front panel c...

Page 13: ...imately 50 times longer than incandescent ones with a typical life of 100 000 hours as opposed to incandescent lights which rarely last more than about 2 000 hours LED lights are brighter than incande...

Page 14: ...g Voltage 50 A 340 Vac Response Time 1 nanosecond Max Surge Current 6 000 Amps 8 x 20 _s pulse Max Spike Energy 70 Joules per leg Noise Attenuation 20 dB 1 5 MHz to 200 MHz Power Cord Attached 14 gaug...

Page 15: ......

Page 16: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Reviews: