EB 2519 EN
25
Decommissioning and removal
8
Decommissioning and
removal
Risk of bursting in pressure equipment.
The valve and pressure element are pressure
equipment. Improper opening can lead to
bursting of the parts. In the installed state,
the spring in the operating element is pre
-
loaded. Incorrect dismantling will release a
high amount of energy, which may lead to
serious injury.
− Do not dismantle the device.
− Contact SAMSON's After-sales Service for
support concerning maintenance or repair
work or when malfunctions or defects
arise.
Risk of burn injuries due to hot or cold com-
ponents and pipeline.
Valve components and the pipeline may be
-
come very hot or cold. Risk of burn injuries.
−
Allow components and pipelines to cool
down or warm up to the ambient tempera
-
ture.
−
Wear protective clothing and safety gloves.
DANGER
!
WARNING
!
Risk of personal injury due to residual pro-
cess medium in the valve.
While working on the valve, residual me
-
dium can flow out of the valve and, depend-
ing on its properties, cause personal injury,
e.g. (chemical) burns.
Wear protective clothing, safety gloves and
eye protection.
8.1
Decommissioning
1. Close the shut-off valve on the upstream
side.
2. Close the shut-off valve on the down-
stream side.
3. Completely drain the pipelines and
valve.
4.
Depressurize the plant.
5. If necessary, allow the pipeline and de-
vice to cool down or warm up to the am-
bient temperature.
8.2
Removing the valve from
the pipeline
1. Put the device out of operation. See sec-
2.
Unbolt the flanged joint.
3. Remove the valve from the pipeline.