![Samson 45-6 Mounting And Operating Instructions Download Page 53](http://html1.mh-extra.com/html/samson/45-6/45-6_mounting-and-operating-instructions_3967653053.webp)
EB 3226 EN
11-1
Removal
11 Removal
The work described in this section is only to
be performed by personnel qualified for the
assignment accordingly.
Risk of burn injuries due to hot or cold
components and pipeline.
Regulator components and the pipeline may
become very hot or cold. Risk of burn inju
-
ries.
Î
Allow components and pipelines to cool
down or heat up.
Î
Wear protective clothing and safety
gloves.
Risk of personal injury due to residual
process medium in the regulator.
While working on the regulator, residual
process medium can escape and, depending
on its properties, may lead to personal in-
jury, e.g. (chemical) burns.
Î
Wear protective clothing, safety gloves
and eye protection.
Before removing the valve, make sure the fol
-
lowing conditions are met:
−
The regulator is put out of operation (see
the 'Decommissioning' section).
WARNING
!
WARNING
!
WARNING
!
11.1 Removing the regulator
from the pipeline
1. Support the regulator to hold it in place
when separated from the pipeline (see
the 'Shipment and on-site transport' sec-
tion).
2. Undo the pipe connections.
3. Remove the regulator from the pipeline
(see the 'Shipment and on-site transport'
section).
Summary of Contents for 45-6
Page 14: ...2 2 EB 3226 EN Markings on the device...
Page 38: ...8 4 EB 3226 EN...
Page 50: ...9 12 EB 3226 EN Servicing...
Page 54: ...11 2 EB 3226 EN...
Page 56: ...12 2 EB 3226 EN...
Page 58: ...13 2 EB 3226 EN...
Page 62: ...14 4 EB 3226 EN...
Page 68: ...15 6 EB 3226 EN Annex...
Page 69: ......
Page 70: ......
Page 71: ......