Samson 1634666 Instruction Manual Download Page 1

DOC4000G

INSTRUCTION MANUAL FOR SAMSON VACUUM LIMITER

VACUUM LIMITER

INSTRUCTION MANUAL

Accessories

•   Technical data

•   Functional description

•   Installation

•   Adjustment

ATEX APPLICABLE

Summary of Contents for 1634666

Page 1: ...DOC4000G INSTRUCTION MANUAL FOR SAMSON VACUUM LIMITER VACUUM LIMITER INSTRUCTION MANUAL Accessories Technical data Functional description Installation Adjustment ATEX APPLICABLE...

Page 2: ...2...

Page 3: ...of incorporation 4 1 2 Explanation of warning symbols 5 1 3 Functional description 5 2 Technical data 6 2 1 Materials 6 2 2 Sectional drawing 6 2 3 Dimensions 7 3 Installation adjustment 8 3 1 Install...

Page 4: ...on source The ATEX Directive 2014 34 EU does not apply to this product The product may be used within the Ex area Applied harmonized standards in particular DS EN 1127 1 2011 Explosive atmospheres Exp...

Page 5: ...supplied to the suction side of the pump through the vacuum limiter which is regulated according to the required pressure Cavitation arises when the pressure in the pump falls to under the steam press...

Page 6: ...5 Membrane housing lower PEHD antistatic 6 Spring guide POM 7 M6x25 allen screw DIN 912 A4 8 M6 nut DIN 934 A4 9 M6 washer A4 10 M6 set screw DIN 916 A4 11 O ring 8x2 NBR Shore 70 12 Spring A2 13 O r...

Page 7: ...45 136 30 15 1 BSP 80 0 80 5 Nipple hose 6 1 8 BSPT 2 3 Dimensions DOC1634666_1 Weight kg 0 5 Vacuum limiter 7...

Page 8: ...w counter clockwise direction Step 2 Open the valve by turning the set srew clockwise direction until the required set pressure is reached It is recommended to adjust the valve to the lowest set press...

Page 9: ...Notes Vacuum limiter 9...

Page 10: ...Notes 10...

Page 11: ...Notes Vacuum limiter 11...

Page 12: ...ough to simply produce a pump Products must be refined so the customer can concentrate on what they do best We therefore offer a wide range of standardised components that allow our customers to build...

Reviews: