20
The pipe connection between the liquid separator and pump must be inspected at least once a month, and
any contaminants must be removed.
5.4 Inspection and cleaning of service liquid’s supply pipe
Over-lubrication of bearings may result in bearing damage! Do NOT exceed the
amount of grease specified below!
5.3 Lubrication of bearings
The bearings must be lubricated with grease of type SKF LGWA2, per 500 duty hours.
It is recommended to lubricate the bearings while pump is running.
DOC1627349_7A
NDE
DE
DOC1627349_7A
Lubrication interval per 500 duty hours
Drive end (DE)
11 g
Non drive end (NDE)
6 g
The pump is designed with internal water channels for lubrication of the mechanical shaft seals.
Remove the plug as illustrated below and clean the channel using a ø5 mm 150 mm long screw driver or
similar.
5.5 Inspection and cleaning of internal channels
DOC1627349_10
DOC1627349_10