3.6 Service liquid requirement
If sea water is used as sealing water, it is recommended to flush the pump with fresh water (inlet A or B)
after use and drain the pump (outlet C) afterwards. See illustration below.
Before the pump is started again, remember to fill the pump to about shaft height before start up.
Otherwise the pump will be started with dry run of the mechanical shaft seals, which will shorten the
lifetime.