TECHNICAL SUPPORT AND SERVICE

Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In 

the event that problems that occur can not be resolved, or if you have any questions regarding this 

equipment or information about other products produced from Sams elektronik, contact your local sales 

representative or call Sams elektronik directly through one of the ways listed below:

Sales: +381 11 3806 254

Technical support: +381 11 2402 212

Service: +381 11 4056 051

Email: 

Sales - [email protected]

Technical support and service - [email protected]

Web site: www.sams.rs

Address: 

SAMS ELEKTRONIK d.o.o.

48 Zivka Davidovica st

11050 Belgrade

Serbia

WARNING

TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.

DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1.   Read all safety and operating instructions before using the device.

2.   Keep all safety and operating instructions.

3.   Follow the instructions from the user manual.

4.   Do not upgrade device, except in the case advised by the manufacturer.

5.   Do not use the device in the presence of water and / or moisture.

6.  Do not pour water or moisten the device with any type of liquid.

7.   Openings on device are provided for ventilation.

8.  Do not block air flow through the ventilation openings.

9.   This product is powered by AC ~ 230V ± 10%, 50Hz.

10.   This product is equipped with a three-wire cord with grounding.

11.  This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.

12.  Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.

13.   Do not bend the power cord so that it can be damaged.

14.  Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted 

for the inputs and outputs of the device can cause severe damage and warranty void.

15.  Do not use the device in an environment that contains flammable or explosive materials in any 

physical state.

16.   Turn off the power corde before cleaning. Do not use liquid, aerosol or flammable cleaners. Use 

only a dry cloth.

17.   Servicing  is  performed  by  a  qualified  person.  Removing  the  cover  user  is  exposed  to  high 

voltages.

18.   Never use the device when the cover is open and the device is powered on.

19.  Do not expose to extreme high or low temperatures.

20.  Do not expose to sudden temperature changes.

21.   Call service in the following cases:

 

- The power cord or plug is damaged

 

- Liquid or foreign objects is inside the device

 

- The machine is exposed to water and moisture

 

- The device does not function according to specification

 

- The unit has been dropped or damaged

 

- The characteristics are significantly changed 

22.   Use only specified replacement parts. 

23.   Professional person authorized by the manufacturer must check the device after completion of 

service.

24.   Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the 

device.

Pictures and drawings listed in this user manual are for information purposes only and may differ 

from the actual device. Design and specifications of the device may change without prior notice.

Summary of Contents for VA-16eql

Page 1: ...on 1 Code 007 165 007 166 007 167 007 162 007 163 007 164 ENGLISH VA14eql 24eql 34eql VA16eql 26eql 36eql Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381...

Page 2: ...facturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consum...

Page 3: ...f high voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with...

Page 4: ...device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power...

Page 5: ...ww sams rs elektronik 5 Distribution amplifiers UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 INSTALLATION 13 ADJUSTMENT 14 REMARKS 15 ACCESS TO ADJUST TRIMMER 15 NOTE...

Page 6: ...The device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited an...

Page 7: ...l INPUT Video Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 6 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB...

Page 8: ...ideo Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 6 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB Gain stab...

Page 9: ...ideo Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 6 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB Gain stab...

Page 10: ...PUT Video Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 4 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB Gain...

Page 11: ...Video Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 4 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB Gain st...

Page 12: ...Video Input Level 1V p p nominal Input Impedance 75 loop trough differential Coupling AC DC jumper selectable OUTPUT Number 4 BNC Level 1V p p nominal Impedance 75 PERFORMANCE Gain 3dB do 3dB Gain st...

Page 13: ...T OPEN CAUTION RIZIK OD STRUJNOG UDARA NE OTVARATI DOK JE POD NAPONOM UPOZORENJE USE ONLY WITH A 250V FUSE www sams rs Made in Serbia VA 4eql CODE 007 165 SN FUSE 500mA AC 230V 50Hz POWER VIDEO OUTPUT...

Page 14: ...rt test 75 Color bar Using a measuring instrument note whether there is a deviation Slowly turn the GAIN potentiometer to adjust the signal level at 1V p p 2 EQ is the process of adjusting the balance...

Page 15: ...ng in the panel It can be adjusted by turning the trimmer ACCESS TO ADJUST TRIMMER REMARKS Loop must be closed with 75 terminator if not used Loop is used to pass incoming signal back into the system...

Page 16: ...VA elektronik Sams elektronik d o o sams sams rs www sams rs 16 Distribution amplifiers NOTES...

Reviews: