SPECIFICATION
VER 1.0
- 2- 5-
2.4.16
External user controls : (With OSD Control)
RGB : BRIGHTNESS CONTRAST
V-SIZE
H-CENTER
H-WIDTH
H-PHASE
PINCUSHION TRAPEZOID
PARALLELOGRAM
ROTATION
R-GAIN
G-GAIN
B-GAIN
AV. : BRIGHTNESS
CONTRAST
COLOR
TINT
SHARPNESS
R-GAIN
G-GAIN
B-GAIN
COMMON : POWER
MUTE
DEGAUSS
WOOFER
VOLUME RECALL
INPUT
BASS
TREBLE
BALANCE
FRONT PANEL FUNCTION KEY : /-
INPUT SELECT
DEGAUSS,
MENU +/-
POWER SWITCH
3.
MECHANICAL REQUIREMENTS
3.1.
Unit dimension (with base) :
Packaging dimension :
W (886) x H (718) x D (583) mm
W (1035) x H (888) x D (765) mm
3.2.
Net weight of unit :
71Kgs
4.
Environmental requirements
4.1.
Non-operating
a. Ambient temperature
- 15 degree C to 50 degree C (5 degree F to 122 degree F)
b. Relative humidity
10% RH to 95% RH (non-condensing)
c. Altitude
10,000 feet
4.2.
Operating
a. Ambient temperature
0 degree C to 40 degree C (32 degree F to 104 degree F)
b. Relative humidity
10% RH to 95% RH (non-condensing)
c. Altitude
10,000 feet
5.
Reliability requirement
The MTBF needs 40000 hours (excluding tube) under operating at 25
†
†
†
†
5 degree C (77
†
†
†
†
41
degree F) ambient temperature also with the normal characters filled within the whole image
screen.
6.
Regulatory requirements
6.1.
Safety requirement.
The unit shall conform to the following safety regulatory standards.
a. UL 1950
Safety of Information Technology Equipment Including Electrical
Business Equipment
b. CSA 22.2
No.
950-M89
Safety of Information Technology Equipment Including Electrical
Business Equipment
c. TUV
No.
EN 60950
EN 60065
Safety of Information Technology Equipment Including Electrical
Business Equipment