4 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 5
SeCtION 2 |
layout, Dimensions &
Input/Output Connections
Fig. 2.1 Layout and Input/Output Connections
1
2
5
3
4
6
Fig. 2.1 FRONT VIEW
12
9
9
8A
8B
10
7A
7B
11A
11B
48V Battery
48V Load
F1
Fig. 2.1 BACK VIEW
F2
Legend - Fig 2.1
FRont VieW
1
AC Power ON/OFF Switch
Illuminates RED when ON
2
AC Input Breaker
25A.
3
DC Volt Meter / Ammeter
Voltage / current on Load Terminals
4
Voltmeter / Ammeter Selector Switch
Switches display on Voltmeter / Ammeter (3)
5
Green LED for Power Supply Modules (PSM)
1 to 5
SteADY on:
PSM is operating normally
BLinkinG:
No output. PSM is not synchronizing
oFF:
No output. Defective
6
Red LED for fan failure or over temperature
of heat sink on the PSM
SteADY on
: Fan failure or PSM over temperature
BAck VieW
7A
Positive (+) Load Terminal
tUBULAR HoLe
: 5/16” Diameter
Set ScReW:
5/16” X 3/8” Long x 24 TPI
7B
Negative (−) Load Terminal
8A
Positive (+) Battery Terminal
8B
Negative (−) Negative Terminal
9
Cooling Fan
2 x 48V fans. Run continuously
10
Grounding Lug
Connect to Earth Ground / System Ground
11A
Attached AC Input Power Cord
3 Conductors - each AWG #12
11B
AC Input Power Cord Plug
30A, NEMA L5-30P
12
DB-25, D-Sub Connector
For remote signaling (Pin Out - Fig 3.2)
F1
External Battery Side Fuse
25A, 80V (Not supplied)
- ATO Style, FKS Series by Littelfuse
- Part No. 166.7000.525
F2
External Load Side Fuse
Summary of Contents for SEC-4825BRM
Page 34: ...34 SAMLEX AMERICA INC Notes ...
Page 35: ...Notes ...