3 YEAR LIMITED WARRANTY

SEC-1212/SEC-1223 manufactured by Samlex America, Inc. (the “Warrantor“) is warranted 
to be free from defects in workmanship and materials under normal use and service. The 
warranty period is 3 years for the United States and Canada, and is in effect from the date 
of purchase by the user (the “Purchaser“). 

Warranty outside of the United States and Canada is limited to 6 months. For a warranty 
claim, the Purchaser should contact the place of purchase to obtain a Return Authorization 
Number. 

The defective part or unit should be returned at the Purchaser’s expense to the authorized 
location. A written statement describing the nature of the defect, the date of purchase, 
the place of purchase, and the Purchaser’s name, address and telephone number should 
also be included. 

If upon the Warrantor’s examination, the defect proves to be the result of defective mate-
rial or workmanship, the equipment will be repaired or replaced at the Warrantor’s option 
without charge, and returned to the Purchaser at the Warrantor’s expense. (Contiguous US 
and Canada only). 

No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is 
unable to remedy the defect after having a reasonable number of opportunities to do so. 
Warranty service shall be performed only by the Warrantor. Any attempt to remedy the 
defect by anyone other than the Warrantor shall render this warranty void. There shall 
be no warranty for defects or damages caused by faulty installation or hook-up, abuse or 
misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or 
water immersion. 

No other express warranty is hereby given and there are no warranties which extend 
beyond those described herein. This warranty is expressly in lieu of any other expressed 
or implied warranties, including any implied warranty of merchantability, fitness for the 
ordinary purposes for which such goods are used, or fitness for a particular purpose, or any 
other obligations on the part of the Warrantor or its employees and representatives. 

There shall be no responsibility or liability whatsoever on the part of the Warrantor or its 
employees and representatives for injury to any persons, or damage to person or persons, 
or damage to property, or loss of income or profit, or any other consequential or resulting 
damage which may be claimed to have been incurred through the use or sale of the equip-
ment, including any possible failure of malfunction of the equipment, or part thereof. The 
Warrantor assumes no liability for incidental or consequential damages of any kind.

Samlex America Inc. (the “Warrantor”)
www.samlexamerica.com

Summary of Contents for SEC-1212

Page 1: ...Switch Mode DC Power Supplies SEC 1212 SEC 1223 Please read this manual BEFORE installing your Power Supply Owner s Manual ...

Page 2: ...afety Instructions 3 SECTION 2 Layout Dimensions 4 SECTION 3 Product Overview 6 SECTION 4 Troubleshooting Guide 8 SECTION 5 Limiting Electromagnetic Interference 9 SECTION 6 Specifications 12 SECTION 7 Warranty 14 OWNER S MANUAL Index ...

Page 3: ...ng Turning off controls will not reduce this risk 3 An extension cord should not be used unless absolutely necessary If an extension cord must be used make sure that the pins on the plug are the same number size and shape as those of the original power supply plug 4 Place the unit in an area that will allow air to flow freely around the unit DO NOT BLOCK OR OBSTRUCT vent openings on the side botto...

Page 4: ...320 C13 connector on one end and NEMA5 15P plug on the other end 3 Black Negative DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 4 Red Positive DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 5 Air inlet slots for cooling fan cooling fan and air outlet slots at the bottom not shown Dimensions WxDxH 185 x 208 x 59 5 mm 7 2...

Page 5: ... 320 C13 connector on one end and NEMA5 15P plug on the other end 3 Black Negative DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 4 Red Positive DC Load Terminal Tubular hole Dia 5mm 0 2 and set screw slot head 10 24 TPI 5 16 long 5 Air inlet slots for cooling fan cooling fan and air outlet slots at the bottom not shown Dimensions WxDxH 185 x 208 x 61 mm 7 28...

Page 6: ...plugging the unit to the AC outlet please check that your local supply voltage is 120 VAC NOTE The DC output connector RED BLACK has a tubular hole of diameter 0 2 5mm with a set screw For a firm connection crimp solder pin type copper terminal on the cable ends of your 12V DC device 2 Pin Type of terminals have been supplied with the unit Ensure that the power supply s ON OFF switch is off and it...

Page 7: ...5ºC 5ºC 167ºF 9ºF PLACE THE SEC 1223 UNIT IN A WELL VENTILATED OPEN AND COOL AREA DO NOT BLOCK THE OPENINGS AT THE FAN DISCHARGE ON THE BOTTOM AND THE SUCTION OPENINGS ON THE SIDES BATTERY CHARGING BATTERY BACK UP WARNING These units are power supplies and not battery chargers Do not connect these units directly to a battery These units should NOT BE DIRECTLY CONNECTED TO A BATTERY for charging or...

Page 8: ...omatically when the transformer windings cool down to 75 C 5 C 167 F 9 F ON OFF Switch is ON Switch is lighted DC Output voltage drops If the voltage loses regulation and drops to 13 5V the unit is overloaded and is in current limit The load is trying to draw the current limit value If the voltage drop is consider able with voltage 2V the load side is seeing a short circuit and short circuit curre...

Page 9: ... due to their fast switching current transitions harmonics of the switching frequency and broadband noise created by under damped oscillations in the switching circuit The secondary source is from the bridge rectifier both rectifier noise and diode recovery The AC input rectifier capacitor in the front end of the SMPS excepting those with Power Factor correction generate power sup ply harmonics du...

Page 10: ...ers The RF absorption of the ferrite coated cable avoids resonances at high frequencies reducing the conducted and radiated RF noises even further For example consider suitability of EMC Cord IMU 14 from EMC Eupen www emceupen com or similar Use additional appropriate DC radio frequency interference RFI power line filter rated for minimum 30 A immediately after the DC output of the power supply Fo...

Page 11: ...mally installed in AC Branch Circuits feeding power outlets in wet areas like marine craft RVs spas hot tubs kitchens washrooms etc As explained earlier RF noise filtration circuits in SMPS generate intentional Earth Leakage Current SMPS are used extensively as DC power sources in modern day electrical elec tronic devices e g Audio Video Computing devices power supplies battery chargers etc A sing...

Page 12: ...idth Modu lation PWM Output Side Switching Frequency 20 KHz 25 KHz PROTECTIONS Short Circuit Overload Constant Current Limiting at 14A Auto Reset Constant Current Limiting at 25A Auto Reset Over Voltage Regulated by PWM Controller Over Temperature Cooled by convection No protection is necessary Output shuts down when Power Transformer winding temperature 105 C 5 C 221 F 9 F Auto reset on cooling d...

Page 13: ...ed FCC Part 15 B Class B INPUT OUTPUT CONNECTIONS AC Input Connection IEC 320 C14 Inlet Connector on the unit Detachable Power Cord with IEC 320 C13 Connector on one end NEMA5 15P Plug on the other end DC Output Connectors Terminal with Tubular Hole Diameter 5mm 0 2 and set screw 10 24 TPI 5 16 long ENVIRONMENTAL Operating Temperature Range 0 C 32 F to 30 C 86 F 0 C 32 F to 40 C 104 F DIMENSIONS A...

Page 14: ...ng a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of the equipment including exposure to excessive heat salt or fresh water spray or wat...

Page 15: ...NOTES ...

Page 16: ... 561 5885 Fax 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders samlexamerica com 11001 SEC 1212 1223 1114 ...

Reviews: