SAMLEX AMERICA INC. | 3
SECTION 1:
SAFETY
1.1 Before using this Remote Control, please follow the Safety Instructions
given in the Owner’s Manual for the inverter PST-3000-12 / PST-3000-24.
SECTION 2 |
DESCRIPTION
2.1 RC-300 is a wired Remote Control that is compatible with inverter model
numbers PST-3000-12 and PST-3000-24.
2.3 It is used to switch ON and switch OFF the inverter from a remote location.
It also displays the operational status using LCD display and colored LEDs.
It is provided with 25 ft / 7.62 meters of connecting cable set with RJ-50
Modular Plugs (10P10C). The conductors of the cable set have crossed-over
(rolled-over) connections on the two RJ-50 plugs.
SECTION 3 |
LAYOUT OF CONTROLS, INDICATIONS
& DIMENSIONAL DRAWING
3.1 Fig. 1 (page 4) shows the layout of controls and indications and dimen-
sional drawing.
3.2 ON/OFF Control
ON/OFF Push Button (1) is used to switch ON and switch OFF the inverter. Every
time the ON/OFF Push Button is pressed, a beep will be heard.
This Remote Control will operate only after the inverter PST-3000 has been first
turned ON using the local ON/OFF Switch on the inverter or using external
ON/OFF control provided in the inverter. Read under heading "Optional Wired
Remote Control - Model RC 300" in Section 8 of Owner's Manual for PST-3000.
3.3 LCD Display
LCD screen (3) is used to display the following 6 output parameters in a sequential
loop as given below.
The screen changes to show the successive parameter in a sequential
manner every time the “Display Push Button” (2) is pressed (Sequence is:
Screen1-2-3-4-5-6-1-2-3…)
1.
AC output voltage in Volts, V
2.
AC output current in Amps, A
3.
AC output frequency in Hertz, Hz
4.
Active AC output power in Watts, W - The display is limited to a
range of 6W - 3500W
5.
Apparent Output Power in Volt Amps, VA
6.
Power Factor, PF