www.larius.com
12
VIKING LINER PLUS 2K
ED. 03 - 01/2021 - Cod. 150161
H
The high speed of travel of the product in the hose
can create static electricity through discharges
and sparks. It is suggested to earth the equipment.
The pump is earthed through the earth cable of
the supply.
The gun is earthed through the high pressure
flexible hose.
All the conductors near the work area must be
earthed.
Avoid approaching too much to the pump piston
rod when the pump is working or under pressure.
A sudden movement of the piston rod can cause
wounds or finger squashing.
Never spray over flammable products or solvents
in closed places.
Never use the tooling in presence of potentially
explosive gas.
Always check that the product is compatible with
the materials composing the equipment (
pump,
spray gun, flexible hose and accessories
) with
which it can come into contact. Never use paints
or solvents containing Halogen Hydrocarbons
(
as the Methylene Chloride
). If these products
come into contact with aluminium parts can
provoke dangerous chemical reactions with risk
of corrosion and explosion.
If the product to be used is toxic, avoid inhalation
and contact by using protection gloves, goggles
and proper face shields.
Take proper safety measures for the protection
of hearing in case of work near the plant.
I
Fig. 1I
The conditions of guarantee do not apply in the
following situations:
- improper washing and cleaning of components
causing malfunction, wear or damage to the
equipment or any of its parts;
- improper use of the equipment;
- use that does not conform with applicable
national legislation;
- incorrect or faulty installation;
- modifications, interventions and maintenance that
have not been authorised by the manufacturer;
- use of non-original spare parts or parts that do
not correspond to the specific model;
- total or partial non-compliance with the
instructions provided.
CONDITIONS OF GUARANTEE
TUBES CONNECTION
Flexible re-circulation tube connection from the tank to the re-circulation group
• Connect the flexible re-circulation tube of
product 1
(
I1
) to the connector (
I2
) ensuring to tighten the fittings
(the use of two wrenches
is suggested)
and insert the tube in the tank (
I3)
as indicated in figure. Repeat the same operations for tubes of
product 2.
I3
I1
I2