We Larius S.r.l.
Via Stoppani, 21
23801 Calolziocorte (LC)
declare under our sole responsability that the product:
NOVA series pneumatic piston transfer pump.
to which this declaration relates complies with the following
directives:
- Directive 94/9/EC (ATEX)
The conformity are under observance of the following standards
3
X
or standards documents:
- EN 1127-1 - EN 13463-5
- EN 13463-1
Markings
II 2 G c IIB T6 Tamb.: - 20°C ÷ 60°C Tmax. fluid: 60°C
Tech. File:
NOVA/ATX/08
Technical dossier kept on file c/o:
INERIS (0080)
Calolziocorte- LC, 15/12/2008
Signature (LARIUS)
ED.
03 - 10/2020 - Cod. 150087
www.larius.com
29
nova 20:1 ext
Read the indications provided in the user and
maintenance manual carefully prior to installa-
tion. All of the maintenance operations must be
performed according to the indications provided
in the manual.
NOVA series pneumatic piston transfer pump
cannot work without material.
All of the installation and maintenance operations
must be performed by qualified personnel.
• The grounding wire for the pumps indicated above must
be grounded using an appropriate anti-loosening con-
nection.
• The tubes used to connect the delivery and suction lines
must be either metallic, plastic with metallic braid, or pla-
stic with fabric braid and a suitable grounding conductor.
• The pumps must be installed on properly grounded
metallic or antistatic drums.
• The gases or vapours of any flammable liquids present
must belong to group IIB.
• Based on the type of use and the substances employed,
the user must periodically check for any encrustations
and must verify the cleanliness, the wear status and the
correct functionality of the pump on a regular basis.
• The user must periodically clean the suction filter in order
to prevent any solid materials from entering the pump.
The air used to power the pump must be filtered and
must come from a SAFE AREA.
SAFETY INSTRUCTIONS FOR INSTALLATION IN
HAZARDOUS AREAS