background image

www.larius.com

7

P33 1:1

REV.

 01 - 10/2020 - Cod. 150174

Fig. 2H

L

J

K

I

1
2

3

4

5

Pos. Description

1

P33 stubby pump

Air inlet

3

Product outlet

4

Pump extension

5

200 lt drum

SETTING UP AND USE

•  Instal the pump in the drum and screw the threaded ring in the 
drum;

•   Connect the air hose to the manometer situated on the pump;

•  Connect the material hose to the pump;

•  Aprire il rubinetto del manometro.

FOR STUBBY VERSION

•  Put the pump in the support; 

•  Screw the suction hose and insert it in the drum;

•  Carry out the same operations as stated above for long version.

NEW EQUIPMENT WASHING

Each pump is tested in our plant using light mineral oil. I f the 
fluid which must be pumped isn't compatible with the one used 
for the testing then it's advised to flush out the pump before use.

SETTING UP

WORKING

Check all the fittings for connection of the different 
components (pump, flexible hose, etc.) before 
using the equipment

Always avoid working the machine with the 
vacuum pump, without liquid to suct: a pump in 
this situation starts to accelerate the stroke till 
to reach an excessivespeed and it will seriously 
damage the pump.

•  Open the air feeding;

•   Be sure that the distributing valves are opened;

•  Adjust the pressure regulator to obtain from the pump for few 

seconds 5 to 20 cycles per minute;

•  The pump only needs few strokes to start sucting. Nevertherless, 

in  a  big  installation,  can  be  necessary  to  run  the  pump  for 
different minutes, in order to fill all pipes;

•  Use always the lowest necessary pressure to obtain the result 

required;

•  When  the  pump  is  used  for  transfer  of  feeding  operations 

without distributing valve, the pump starts working when the 
air is supplied;

•  In case an air pipe line or a distributing valve is used, release 

the valve to exhaust the fluid pressure in the pipe.

PROBLEMS AND SOLUTIONS

PROBLEMS

The pump accelerates or works too rapidly.

SOLUTIONS

Immediately stop pumping and check the feeding of the fluid 
pumped. If the fluid pumped tends to dry or to harden, fill 

NORME GENERALI DI LUBRIFICAZIONE

•  Grease periodically the piston rod.

•  In  case  of  maintenaince  intervention  on  the  motor,  please 
provide to grease the mechanical parts.

MAINTENAINCE INSTRUCTIONS FOR PACKING GLANDS

The seal between pumping rod and gasket is guaranteed by an 
adjustable  packing  gland.  Tighten  the  packing  gland  without 
forcing, by turning it clockwise in case of possible leaks. Replace 
the packing gland if the leaks do not stop.

GENERAL MAINTENAINCE

Summary of Contents for Larius 3600

Page 1: ... 01 10 2020 Manuale Cod 150174 II 2 G c IIB T4 Stubby version Cod 3610 Stainless steel stubby Cod 3611 Long version Cod 3600 Stainless steel long version Cod 3601 OPERATING AND MAINTENANCE MANUAL EN P33 1 1 Pneumatic tranfer pump ...

Page 2: ... manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian ...

Page 3: ...ange of support services enabling you to achieve the results desired quickly and professionally WARNINGS 2 WORKING PRINCIPLE 3 TECHNICAL DATA 3 DESCRIPTION OF THE EQUIPMENT 4 TRANSPORT AND UNPACKING 5 CONDITIONS OF GUARANTEE 5 SAFETY RULES 5 TYPICAL INSTALLATION 6 SETTING UP 7 PROBLEMS AND SOLUTIONS 7 GENERAL MAINTENAINCE 7 WORKING 7 COMPLETE PNEUMATIC MOTOR P33 1 1 8 PUMPING COMPLETE GROUP P33 1 ...

Page 4: ...t carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not been given IF PROVIDED There is a risk of injury or serious lesion related to contact with the jet from the spray gun If this should occur IMME DIATELY contact a doctor indicating the type of product i...

Page 5: ...cycles for liter 5 Maximum capacity 20 lt min Fedd pressure 3 12 bar Air inlet 1 4 BSPP WORKING PRINCIPLE TECHNICAL DATA P33 1 1 pump is a pneumatic pump designed for the transfer of low viscosity productswith the ability to transfer large quantities of liquid Pump standard versions are manufactured in carbon steel for specialapplications foodstuffsindustry pharmaceutics chemical etc on demand are...

Page 6: ...D 1 1 3 3 5 5 4 4 6 6 7 7 2 2 Pos Description 1 Pneumatic motor group 2 Manometer 3 Outlet material 4 Air inlet Pos Description 5 Grounding cable 6 Pumping material tube 7 Material inlet DESCRIPTION OF THE EQUIPMENT P33 short version pump P33 long version pump ...

Page 7: ...S ABOUT ALL THOSE RISKS STEMMING FROM ACCIDENTS ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE BEHAVIOUR OF THE EMPLOYEES SHALL STRICTLY COMPLY WITH THE ACCIDENT PREVENTION AND ALSO ENVIRONMENTALREGULATIONSINFORCEINTHECOUNTRY WHERE THE PLANT IS IN...

Page 8: ... use paints or solvents containing Halogen Hydrocarbons as the Methylene Chloride If these products come into contact with aluminium parts can provoke dangerous chemical reactions with risk of corrosion and explosion If the product to be used is toxic avoid inhalation and contact by using protection gloves goggles and proper face shields Take proper safety measures for the protection of hearing in...

Page 9: ...air feeding Be sure that the distributing valves are opened Adjust the pressure regulator to obtain from the pump for few seconds 5 to 20 cycles per minute Thepumponlyneedsfewstrokestostartsucting Nevertherless in a big installation can be necessary to run the pump for different minutes in order to fill all pipes Use always the lowest necessary pressure to obtain the result required When the pump ...

Page 10: ...rius com 8 P33 1 1 REV 01 10 2020 Cod 150174 M Fig 1M 1 2 3 4 5 6 7 3 8 9 10 11 16 17 18 19 20 12 13 14 15 ATTENTION always indicate code and quantity of each requested detail COMPLETE PNEUMATIC MOTOR P33 1 1 ...

Page 11: ... Atex plate 1 7 10112 Stainless steel label 1 8 3621 Complete motor piston 1 9 3312 Washer 1 10 3313 Lower piston spring 1 11 3638 Plug 1 12 3624 Piston stem 1 13 3634 Spring 1 14 3635 Complete silincer 1 15 3314 Washer seal 1 16 3623 Motor housing 1 17 3354 Nipples 1 18 3344 Pressure control 1 19 8167 Pressure gauge 1 20 3843 Complete pressure gauge 1 Pos Description 3 PTFE packing 8 Complete mot...

Page 12: ...A LUNGA CORTA 1 2 3 4 5 6 8 9 10 11b 12 11a 12 7 8 8 14 15 16 18 20 21 22 23 24 25 26 17 18 27 28 29 30 31 23 23 32 33 36 34 35 32 9 9 13 13 18 19 34 37 S H O R T SHORT LONG L O N G ATTENTION always indicate code and quantity of each requested detail PUMPING COMPLETE GROUP P33 1 1 ...

Page 13: ...s steel 1 3804 Tie rod long version 1 20 3805 Tie rod stainless steel long version 1 Pos Code Description Q ty 21 3649 Tie rod long version 1 3803 Stainless steel tie rod long version 1 22 3807 Piston upper section stainless steel 1 23 3326 Ball Ø7 8 2 3875 Stainless steel ball Ø7 8 2 24 3808 Stainless steel washer 1 3327 Washer 1 25 3328 PTFE packing 1 26 3809 Piston lower section stainless steel...

Page 14: ...33 1 1 REV 01 10 2020 Cod 150174 O Fig 1O Fig 2O Code Description 3610 P33 short version 3611 P33stainlesssteelshort version Code Description 3600 P33 long version 3601 P33stainlesssteellongversion COMPLETE PUMPS VERSIONS ...

Page 15: ...www larius com 13 P33 1 1 REV 01 10 2020 Cod 150174 ...

Page 16: ...hat the product Company Signature Calolziocorte 13 October 2020 Location Date complies with the directives EC Directive 2006 42 Machinery Directive furthermore to the harmonized standards UNI EN ISO 12100 1 2 Machinery safety basic concepts general principles of design Basic terminology methodology Technical principles This declaration relates exclusevely to the product in the state in which it wa...

Page 17: ......

Page 18: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com ...

Reviews: