For gun scope calibration, go to "TEST MENU" and select "I/O TEST." Screen shows
calibration screen. (Fig.1)
Before Pulling trigger at this screen, please test
all of switches, if necessary.
Screen shows ON or OFF letters for each
switch when they are activated.
After pulling trigger, screen goes to calibration mode.
Screen shows a "White square" in the top left
corner of screen. (Fig.2) Shoot center of this box
using 1 player scope gun.
Then the White Square will move to the right bottom
of the screen. (Fig.3) Shoot center of this box using
1 player scope gun.
The White square will move to center of the screen.
(Fig.4)
Shoot center of this white square using 1 player
scope gun to complete 1 player’s gun calibration.
Then the screen will go to 2 player gun calibration
automatically.
This is the same movements as above 1 player gun
adjustment. Shoot each of the 3 positions of White
square using 2 player scope gun.
After finished with above, pull trigger to exit I/O test.
Please double check gun calibration using normal
game mode. Move gun forward and backward
then shoot screen. Make sure each gun’s hit mark
does not move or jump.
If hit mark moves or jumps, you need monitor adjustment.
Lower brightness or contrast of monitor)
NOTE: Once you are in this mode, you can not
skip calibration of both guns. If you re-power
game during calibration, all settings will revert
to previous data.