background image

Sammode SA 

 

Notice VOUET … SENSOR

 

24 rue des Amandiers, F-75020 Paris 

5/5

 

Octobre 2016 

 

Setting up the sensor

 

Setting a threshold 

 

 
 
 
 
 

Value range

 

 50 lx ; smooth adjustment or disable 

Position I 

Disable 

Position V  

threshold 2 lx

 

 

Setting a detection range 
 
 
 

Value range

 

smooth adjustment; depends on installation height 

Position I 

maximum detection range 

Position V 

minimum detection range

 

 
 

 

 
 
 
 
 
 
 
 
 
 
Setting a run-on time 

 
 
 
 
 
 
 

Value range

 

30 s 

 30 min ; 

smooth adjustment

 

Position VII 

 

30 min 

Position I 

 

30 s 

 

A threshold can be set to prevent the lighting from switching 
on unnecessarily when illuminance levels are sufficient. The 
threshold indicates the maximum illuminance at which the 
lighting switches on if motion is detected. 

he detection range can be restricted to prevent the lighting from switching on unnecessarily because the range is too large. 
The detection range indicates the diameter in which motion is detected.

 

A run-on time can be set to prevent the lighting from switching on and 
off unnecessarily.  The run-on time starts after the last motion has been 
detected. If further motion is registered in the detection range during 
the run-on time, this time starts over again. 

Reviews: