Samlexpower SEC-1212CE Installation & Operating Manual Download Page 5

 

COOLING AND FAN CONTROL / THERMAL SHUT DOWN (SEC-1223CE) 
 

 

SEC-1212CE

 is cooled by convection. 

PLACE THE UNIT IN A WELL VENTILATED OPEN AND COOL AREA.  
DO NOT BLOCK THE VENTILATION OPENINGS ON THE SIDES  

 
 

SEC-1223CE

 is cooled by convection and forced air. A temperature con-

trolled fan has been provided to improve cooling at higher loads. The fan is 
controlled by a sensor mounted on the power transformer. 

THE FAN WILL 

BE OFF AT LOWER LOADS

.  It will come on only when the temperature of 

the power transformer is above 70ºC due to higher loads. In case the fan 
fails or the air flow is blocked, a second temperature sensor mounted on the 
power transformer will activate over temperature shut down at 100ºC.  The 
output voltage will be automatically resumed once the unit cools down. 

PLACE THE UNIT IN A WELL VENTILATED OPEN AND COOL AREA. 
DO NOT BLOCK THE OPENINGS AT THE FAN SUCTION ON THE BOT-
TOM AND THE DISCHARGE OPENINGS ON THE SIDES . 

 
 
 

BATTERY CHARGING AND BATTERY BACK-UP 
 

 

 

 

 WARNING !

  

THESE UNITS ARE POWER SUPPLIES AND 

NOT BATTERY CHARGERS. DO NOT CONNECT THESE UNITS DI-
RECTLY TO A BATTERY 
 

 
These units should 

NOT BE DIRECTLY CONNECTED TO A BATTERY

  for 

charging or for battery back-up. Battery charging and battery back-up may 
be undertaken only when the battery is connected through suitable external 
isolating diodes and charge limiting resistor. The isolating diode will ensure 
that the battery does not back power the power supply.  When a battery is 
deeply discharged, it  will initially draw a very large charging current and 
thus, will force the power supply into current limit mode for prolonged peri-
ods. This is harmful for the power supply. The charge limiting resistor will 
limit the charging current, thereby, ensuring that the maximum charging cur-
rent is well below the current limit value of the power supply. 

WE OFFER OPTIONAL BATTERY BACK-UP AND CHARGING MOD-
ULE . PLEASE CONTACT OUR CUSTOMER SERVICE 

 
 

3. 

Summary of Contents for SEC-1212CE

Page 1: ...MODELS SEC 1212CE SEC 1223CE INSTALLATION OPERATING MANUAL SWITCH MODE DC POWER SUPPLY REGULATED DC POWER SUPPLY...

Page 2: ...safety instructions 1 Description and features 2 Connection and operation 2 Cooling and fan control 3 Battery charging and back up 3 Trouble shooting 4 Switching power supplies RF Noise 5 6 Specifica...

Page 3: ...ape as those of the original power supply plug 4 Place the unit in an area that will allow air to flow freely around the unit DO NOT block or obstruct vent openings on the side bottom of the unit 5 Ke...

Page 4: ...NOTE The DC output connector has a tubular hole of diameter 0 2 5mm with a set screw For a firm connection crimp solder a pin type copper termi nal on the cable ends of your 12V DC device Ensure that...

Page 5: ...S AT THE FAN SUCTION ON THE BOT TOM AND THE DISCHARGE OPENINGS ON THE SIDES BATTERY CHARGING AND BATTERY BACK UP WARNING THESE UNITS ARE POWER SUPPLIES AND NOT BATTERY CHARGERS DO NOT CONNECT THESE UN...

Page 6: ...erload caused by large reactive shorted Remove the load If the output loading or by the output being voltage gets restored the load is shorted short circuited or is offering large reactive impedance U...

Page 7: ...F noise and lose output voltage regulation due to excessive transmitter energy being coupled through the AC DC lines to the power supply s regulator feedback path This may be due to antenna being too...

Page 8: ...at is lacking in most regular LC filters The RF absorption of the ferrite coated cable avoids resonance s at high frequencies reducing the conducted and radiated RF noises even further b Use additiona...

Page 9: ...AND OVER VOLTAGE THROUGH PWM CONTROLLER OVER TEMPERATURE SHUT DOWN FOR SEC 1223CE FUSE RATING 5 MM X 20 MM GLASS FUSE 250 V slow blow SEC 1212CE 2A SEC 1223CE 4A AC INPUT CONNECTION DETACHABLE POWER C...

Page 10: ...Purchaser unless the Warrantor is un able to remedy the defect after having a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remed...

Page 11: ...Notes Attach your original bill of sale here Model No Date purchased Place of purchase Purchase price Serial number SEC 1212CE SEC 1223CE 9...

Page 12: ...Thank you for purchasing a Samlex power supply product Samlex America Inc 110 17 Fawcett Road Coquitlam B C V3K 6V2 Canada SEC 1212CE SEC1223CE 020304...

Reviews: