background image

 

15 

 

 

3-7. Inverter Operation 

To operate the power inverter, use the ON / OFF switch on the Front panel to 
turn the power on. Then the power inverter is ready to deliver AC power to 
the loads. 
If you are operating several loads from the power inverter, turn them on 
separately after the inverter is on. 
This will ensure that the power inverter does not have to deliver the starting 
currents for all the loads at one time. 

3-7-1. Controls and indicators 

The ON / OFF switch turns the control circuit in the power inverter on 
and off.  It does not disconnect power from the power inverter. 
The Inverter operates from an input voltage ranging of

 

10.5 to 15.0 VDC for 12V models 

21.0 to 30.0 VDC for 24V models 

The Inverter will indicate high and low DC voltage conditions as 
follows

 

Model 

Dc Input over  

Voltage shut-

down 

Dc Input under 

Voltage alarm 

Dc Input under 

Voltage shut-down 

SA-600R-112 

15.3 

11.0 

10.5 

SA-600R-124 

30.6 

22.0 

21.0 

15

 

 

 

Summary of Contents for SA-600R Series

Page 1: ...1 SA 600R Series Pure Sine Wave Inverter User s Manual...

Page 2: ...ations 2 2 2 Electrical Performance 3 2 3 Mechanical Drawings 4 3 Instructions 5 3 1 Front Panel Operation 5 6 3 2 Rear Panel Operation 7 8 3 3 Installation 9 3 4 Quick hook up and Testing 10 11 3 5 A...

Page 3: ...1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts your skin or clothing you need to wash it out immediately with soap and water If acid enters into your eyes immediately flush...

Page 4: ...lications 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc 2 1 2 Office equipment computers printers monitors facsimile machines and scanners...

Page 5: ...Regulation 100 110 120V RMS 10 4 Input Voltage Regulation 10 5 15 VDC 21 0 30 VDC Input Level Indicator Red Orange Green LED Load Level Indicator Failure Indicator Red LED Protection Overload Short Ci...

Page 6: ...4 2 3 Mechanical Drawing...

Page 7: ...before you install and operate this model 3 1 Front Panel Operation 3 1 1 Front view PURE SINE WAVE INVERTER 3 1 2 ON OFF switch Leave the switch in the down position OFF during installation 3 1 3 In...

Page 8: ...0W 580W Red Blink Over 580W 3 1 5 Failure Display failure status OVP over voltage protection UVP under voltage protection OTP over temperature protection OLP over load protection 3 1 6 AC outlet Outle...

Page 9: ...perate the inverter with Remote ON OFF switch ON OFF switch on the Front Panel should be off 3 2 1 2 Ensure the remote control contact is off 3 2 1 3 Use 14 20 AWG wire to connect the Rear Panel Termi...

Page 10: ...4V battery or other 12V 24V power source represents positive and represents negative Reverse polarity connection will blow the internal fuse and may damage the inverter permanently 3 2 4 Use wire 8 AW...

Page 11: ...tom of the unit are not obstructed 3 3 5 Dust free Do not install the Inverter in dusty environment The dust can be inhaled into the unit when the cooling fan is working 3 3 6 Close to batteries Avoid...

Page 12: ...wer inverter The red terminal represents positive and black terminal represents negative Insert the cables into the terminals and clamp the nuts and the wires securely WARNING You may observe a spark...

Page 13: ...inally the buzzer will send out another beep sound and the input Level LED indicators will turn to Green color and the inverter starts working successfully 3 4 6 Set the power switch to OFF position t...

Page 14: ...es such as inverters and generators which have their neutral conductors tied to ground in the same way as the neutral conductors from the utility tied to ground at the AC breaker panel For models conf...

Page 15: ...the battery cables to the DC input terminals on the Inverter The cables should be as short as possible less than 10 feet 3 meters ideally and large enough to handle the required current in accordance...

Page 16: ...Samlex recommends the following cables for optimum inverter performance Model No Wire AWG Inline Fuse SA 600R 112 4 100A SA 600R 124 6 50A Also use only high quality copper wiring and keep cable leng...

Page 17: ...he starting currents for all the loads at one time 3 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the powe...

Page 18: ...the lower red zone and cables No output voltage Thermal shutdown Improve ventilation Over Temp indicator on make sure ventilation shafts of the inverter Load less than 600W are not obstructed Lower a...

Page 19: ...s product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us...

Page 20: ...rica Inc 110 17 Fawcett Road Coquitlam BC V3K 6V2 Canada Toll free phone 1 800 561 5885 Toll free fax 1 888 814 5210 General Inquiries samlex samlexamerica com WWW http www samlexamerica com SA 600R_M...