50 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 51
SECTION 12 |
Specifications
MODEL NO. PST-1500-48
PST-600-48
OUTPUT
OUTPUT VOLTAGE
120 VAC ± 3%
120 VAC ± 3%
MAXIMUM OUTPUT CURRENT
12.5A
5.1A
OUTPUT FREQUENCY
60 Hz ± 1%
60 Hz ± 1%
TYPE OF OUTPUT WAVEFORM Pure Sine Wave
Pure Sine Wave
TOTAL HARMONIC DISTORTION
OF OUTPUT WAVEFORM
< 3%
< 3%
CONTINUOUS OUTPUT POWER
(At Power Factor = 1) 1500 Watts
600 Watts
SURGE OUTPUT POWER
3000 Watts (< 8 ms)
1000 Watts (< 8 ms)
PEAK EFFICIENCY
90%
90%
AC OUTPUT CONNECTIONS
(i) NEMA5-20R GFCI Duplex
Receptacle (ii) Terminal block for
hardwiring: Hole diameter (4 mm /
0.16") and Set Screw (#6 x 40TPI or
M3.5 x 0.6 mm Pitch)
NEMA5-20R GFCI Duplex Receptacle
INPUT
NOMINAL DC INPUT VOLTAGE
48 VDC
48 VDC
DC INPUT VOLTAGE RANGE
42.0 - 64.0 VDC
42.0 - 64.0 VDC
MAXIMUM DC INPUT CURRENT
50A
20A
DC INPUT CURRENT AT NO LOAD
< 0.5A
0.3A
DC INPUT CONNECTIONS
Bolt and nut : 5/16" x 18TPI
DC INPUT FUSES (INTERNAL)
5 x 10A = 50A
(Each 10A, 58V, Blade Type)
2 x 10A = 20A
(Each 10A, 58V, Blade Type)
DISPLAY
LED
Power, Overload, Over Temperature
Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM
42.0V ± 0.5V
42.0V ± 0.5V
LOW DC INPUT VOLTAGE SHUTDOWN
40.0 ± 0.5 VDC ; Auto-reset: 46.0 ±
0.5 VDC
40.0 ± 0.5 VDC ;
Auto-reset: 46.0 ± 0.5 VDC
HIGH DC INPUT VOLTAGE
SHUTDOWN
64.0 VDC ; Auto-reset: < 64.0 VDC
64.0 VDC ; Auto-reset: < 64.0 VDC
SHORT CIRCUIT SHUTDOWN
When output voltage drops to 80 VAC or lower for 1 to 1.5 sec
OVERLOAD SHUTDOWN
At overload of 110% to 115% for 2 to 2.5 sec
GROUND FAULT SHUTDOWN
Through GFCI outlets (5 to 6 mA leakage)
OVER TEMPERATURE SHUTDOWN
90°C ± 5°C (Sensed at internal hot spot) ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON
DC INPUT SIDE
External / internal DC sides fuses will blow
REMOTE CONTROL
WIRED REMOTE CONTROL
RC-300 with LCD/LED display
and 7.62m/25 ft cable
(Sold separately)
RC-15A with LED display
and 5m/16.5 ft cable
(Sold separately)
COOLING
FORCED AIR COOLING
2 Temperature controlled fans
1 Temperature controlled fan
(Temperature is sensed at internal hot spot ; Fan ON at 55°C ÷ 3°C ;
Fan OFF at 45°C ± 3°C)
COMPLIANCE
SAFETY
Meets UL Standard UL 60950-1 and CSA Standard C22-2 No.107.1-01
for Information Technology Equipment
EMI / EMC
FCC Part 15(B), Class B
ENVIRONMENT
WORKING ENVIRONMENT
Indoor use
OPERATING TEMPERATURE RANGE
-20˚C to 40˚C / -4˚F to 104˚F
-20˚C to 40˚C / -4˚F to 104˚F
RELATIVE HUMIDITY
Up to 85%, non condensing
DIMENSIONS
(W X D X H), MM
263.0 x 468.2 x 105.6
238 x 276.2 x 82
(W X D X H), INCHES
10.35 x 18.43 x 4.16
9.37 x 10.87 x 3.23
WEIGHT
KG
7.1
2.7
LBS
15.6
5.9
NOTES:
1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25
°
C / 77
°
F.
3. Specifications are subject to change without notice