f.) Remote Operation Socket. The inverter is designed to be operated
from a remote location via the remote control switch which plugs into this
socket. This optional accessory is available from Samlex.

g.) High Speed Cooling Fan. This fan will turn on automatically when
the internal  temperature exceeds design parameters for safe operation.
The Cooling Fan will automatically turn off when the temperature drops to
a safe operating level. This fan does not run continuously.

h.) Power Input Terminals (WHITE/Negative, RED/Positive)

i.) Chassis Ground Terminal Lug

j.) Circuit Breaker. This is provided for PSE-24250A

k.) Punched Holes. These holes are provided for entry of cables going to
the external Breaker Panel (when hard wired)

Page 7

Summary of Contents for PSE-24100A

Page 1: ...Please read this manual before operating your charger D C A C I N V E R T E R S MODELS PSE 24100A PSE 24150A PSE 24250A A C P O W E R S O U R C E OWNER S MANUAL...

Page 2: ...ng proper Wire Cable Sizes 8 Installation Operation 9 Appliances that may not operate correctly on modified sinewave 11 Powering Television Audio Equipment 11 Powering Microwave Ovens 12 Technical Inf...

Page 3: ...the following when the battery is being charged simultaneously the output voltage of the charging device will be fed to the inverter Ensure that the charging voltage of the alternator has not been set...

Page 4: ...esigned to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continu ous wattage rating For example the PSE 24150A model has a maximum continuous ratin...

Page 5: ...f LAYOUT PSE 24100A PSE 24150A PSE 24250A Rear View Bottom View a c d e b g h i Front View b a c d e k j f g h i Rear View Page 4...

Page 6: ...excess temperature the High Speed Cooling Fan also will automatically turn on Overheating may result when the inverter is being operated at levels exceeding its wattage rating or because it has been...

Page 7: ...erate with input voltages ranging from 20 to 30 volts of direct current DC When the voltage drops below 21 volts DC the voltage indicator will register in the lower RED zone and an audible alarm will...

Page 8: ...when the internal temperature exceeds design parameters for safe operation The Cooling Fan will automatically turn off when the temperature drops to a safe operating level This fan does not run contin...

Page 9: ...livered by the battery 2500 Watts divided by 20 125 Amps AH required to be delivered by the battery 125 Amps x 2 Hours 250 AH Hence the AH capacity of the battery should be more than 250 AH or 250 div...

Page 10: ...models BLACK on the PSE 24250A model on the inverter to the Negative terminal on the 24 volt power source Make certain the connection is secure 4 Confirm that the wire you have just installed is prop...

Page 11: ...appliance to be operated is turned off Plug the equipment or appliance into one of the two AC receptacles on the front panel of the inverter 10 Turn the inverter on Turn the equipment or appliance on...

Page 12: ...Although the inverter is shielded and filtered to minimize signal interference some interference with your television picture may be unavoidable especially with weak signals However here are some sugg...

Page 13: ...ET transistors The output waveform resulting from this conversion is a quasi sine wave or a modified sine wave as shown below This stepped waveform is nearly similar to the sinewave power generated by...

Page 14: ...wet Water and many other liquids can conduct electricity which may lead to serious injury or death HEAT The ambient air temperature should be between 50o and 80o F Avoid placing the inverter on or nea...

Page 15: ...e rated power consumption of the equipment is in the range of the rated capacity of the inverter test the inverter to ensure that it will operate properly When attempting to recharge battery chargers...

Page 16: ...LOAD RED LED FOR OVERTEMP Input side DC Fuses Automotive Type ATC 32V ENVIRONMENT CONDITIONS Operating Temp deg C Storage Temp deg C Relative Humidity OUTPUT CONNECTORS Wires for connection to externa...

Page 17: ...sing incorrect type of voltmeter Use true RMS reading meter See Page 12 Technical Information Automatic Shutdown due to input voltage beyond 30V this may permanently damage the inverter Charging alter...

Page 18: ...ong Use lower gauge wire See battery cables which cause excessive Page 8 Wire Cable Sizes section of voltage drop this manual Keep wire length as short as possible PROBLEM TV Interference REASON POSSI...

Page 19: ...______________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________...

Page 20: ...110 17 Fawcett Road Coquitlam B C Canada V3K 6V2 e mail samlex samlexamerica com website www samlexamerica com Version C 101002...

Reviews: