DESCRIptIon, fEatURES & applICatIonS
IDC-360 Series offer 360W capacity Isolated DC-DC Converter models covering wide range of DC input voltages of 12V/24V/48V/72V and outputs
of 12V/24V/48V. Design features include:
- Advanced Switch Mode Technology with fixed frequency PWM control for optimum efficiency and reliability and compact size
- Galvanic isolation between input and output sides with following benefits:
- Noise on the input side is isolated from the output side for noise sensitive loads like radios, instrumentation, data processing etc.
- Converts Positive voltage to Negative voltage with respect to common, non-insulated ground. For example, IDC-360C-12 can convert - 48VDC
of telecom supply to +12VDC supply
- Can be used to create either Negative isolated or Positive isolated Rail using single unit or dual Positive and Negative isolated Rails using 2
units in series.
- Protections against short circuit/overload, input over voltage/transients, output over voltage, over heating and reverse polarity;
- Compliance with European EMI/EMC and Automotive Standards
Applications include noise sensitive loads like radios, instrumentation and data processing for isolated input and output grounds and telecom,
tractor trailers, buses, forklifts, heavy machinery, locomotive/railroad, marine and aviation for non-isolated, common input and output ground.
InStallatIon & opERatIon
WaRnInG!
This unit is NOT a Battery Charger. Please do not use to charge a battery.
General Installation Requirements
- The unit is cooled by a temperature controlled fan. Install the unit in a cool, dry and well ventilated space. Do not block fan vent openings on
the sides.
- Do not install the unit inside engine compartment.
- Do not connect/disconnect input and output connections when live voltages are present.
For more information on input / output grounding e.g. installation on Positive Grounding System, refer to www.samlexamerica.com under:
Support
Ò
Application Notes
Ò
DC-DC Converters
−
Input and Output Grounding.
fusing on the Input & output Sides
The input side of the unit will be connected to the battery. A battery has the capacity to supply very large currents. In case there is a short circuit between
the input side wiring, very heavy current will flow and will burn/melt the wiring and may be a fire hazard. To prevent this, use a suitable fast blow fuse
(see Table 1) in line with the Positive input wire within 7" from the battery Positive terminal. The output side should be connected through a suitable fuse
in line with the "" terminal (see Table 2).
WaRnInG!
The Warranty will be voided if proper fuse is not used as recommended.
Switching on & Switching off arrangement on the Input Side
There is no ON/OFF switch on the input side of the unit. An external ON/OFF switch may be used in series with the Positive input wire, if required.
Sizing of Input and output Wiring
In order to prevent excessive voltage drop and consequent loss of current capacity and efficiency, use proper size of input and output wires. Please
note that as the current/length of wiring are increased, the thickness of the wiring will also be required to be increased. The thickness of wires and
cables is normally expressed in AWG (American Wire Gauge). Also, note that a lower AWG number denotes a thicker wire. Use multi-stranded
copper insulated wiring rated for at least 90oC/194oF. Please refer to details of input/output wire sizes (Tables 1 and 2).