type of Input and output Connections

The unit has a terminal block with 4 male, quick connect flat blade type terminals (6.3 mm / ¼ in) for quick connection/disconnection (see Fig 2). Two 
blades are for input (Marked “Input +” and “Input –”) and two are for output (Marked “Output -” and “”). The wiring for connection to 
the terminals should be terminated with the corresponding female quick connect terminals meant for the above male 6.3 mm / ¼ in flat blade type 
terminal.    

Making Input & output Connections & operation 

CaUtIon!

 Please ensure that the polarity of the input connection is not reversed. Connect the Positive of the battery to the Positive terminal 

and the Negative of the battery to the Negative. In case the input polarity is reversed, the unit will be damaged and 

will not be covered 

under Warranty

.

-  Input and output connections should not be made when live voltages are present.
- Switch 

OFF the load that is required to be powered from the converter.

-  Connect the output wires to the load and then to the output side of the unit through the external fuse. 

OBserVe COrreCT POLAriTy. 

- Switch 

OFF the external inline input side switch (if used) and also remove the external inline fuse in the Positive input wire.

-  Connect the input side wires to the converter’s input side first. 

OBserVe COrreCT POLAriTy. 

-  Connect the input wires to the battery.
-  Insert the external inline input side fuse in the Positive input wire. 

NOTe:

 If an ON/OFF switch is not used in series with the Positive input wire or 

if a switch has been used and has not been switched OFF, a spark may be observed when inserting the fuse due to the initial inrush current to 
charge the input side capacitors inside the converter.

 -  Switch on the input power to the unit (if an external switch has been used). Output voltage will now be available on the output side of the unit.
- Switch 

ON the load.

protections 

overload/Short Circuit: 

Overloading beyond the maximum output current value (16A for IDC-200x-12 and 8A for IDC-200x-24) will produce 

voltage drop on the output side. The output will recover automatically once the overload condition is removed.  Under short circuit conditions on 
the output side, the voltage will drop to a very low value, output current will rise beyond the rated value and external fuse will blow if short circuit 
condition persists for longer duration. There is automatic reset if the short circuit condition is removed before the fuse blows.  

Reverse polarity / over Voltage on the output Side: 

In case of (i) overvoltage on the outside (18V for 12V, 30V for 24V and 60V for 48V) or 

(ii) reverse polarity on the output side, internal Zener Diode across the output terminals will conduct and blow the external fuse on the output side. 

over Voltage/transients on the Input Side: 

A Metal Oxide Varistor (MOV) across the input terminals provides protection against high voltage 

transients by blowing the internal input side fuse.  NOTE: This protection is not available in IDC-200C / IDC-200D.

Reversal of polarity on the Input Side Connection:

 IDC-200A / IDC-200B: In case of reversal on input side polarity, internal diode connected 

across the input terminals will conduct and will blow the input side fuse. IDC-200C / IDC-200D: Internal diode in series with the Positive input line 
wil block Negative input voltage. 

fan Cooling: 

The unit is cooled by 1 temperature controlled fan (7, Fig 2). Temperature of internal hot spot is sensed and at 45°C, the fan is 

switched ON. The fan is switched OFF automatically when the internal hot spot temperature cools down to 40°C 

over temperature:

 In case of higher ambient temperature or fan failure or blockage of fan suction / exhaust openings, the temperature of 

the internal hot spot may rise beyond permissible limits. At >70°C, the output voltage will start dropping to reduce the output current. If the 
temperature still continues to rise, the output will be shut down at 80C. The unit will reset automatically when the unit cools down to 70°C. 

output Current De-rating at ambient temperature > +30°C: 

The unit is designed to provide the full rated output current up to ambient 

temperature of +30°C. The output current will be required to be reduced (de-rated) linearly from the full rated Amps at +30°C to 0 Amps at +70°C. 

For example, IDC-200A-12 will provide full rated current of 16A till +30°C. The load current should be linearly reduced to 0A at +70°C (At +70°C, 
over temperature protection will be initiated and the output voltage will drop). This means that the output current capacity should be reduced 
linearly at the rate of 0.4A/°C for every 1°C rise higher than +30°C. At say +50°C, the maximum permissible output current should be reduced to 
8A [16A – {(50C – 30C) x 0.4A /°C}].     

Summary of Contents for IDC-200

Page 1: ...temperature controlled fan Install the unit in a cool dry and well ventilated space Do not block fan vent openings on the sides Do not install the unit inside engine compartment Do not connect disconnect input and output connections when live voltages are present For more information on input output grounding e g installation on Positive Grounding System refer to www samlexamerica com under Suppor...

Page 2: ...rent will rise beyond the rated value and external fuse will blow if short circuit condition persists for longer duration There is automatic reset if the short circuit condition is removed before the fuse blows Reverse Polarity Over Voltage on the Output Side In case of i overvoltage on the outside 18V for 12V 30V for 24V and 60V for 48V or ii reverse polarity on the output side internal Zener Dio...

Page 3: ...LE 2 External Output Side Fuse Wiring Model Name Fuse Specs WIRE SIZE Up to 6 ft from Battery see Note 1 below IDC 200A 12 32V 20A AWG 10 IDC 200B 12 32V 20A AWG 10 IDC 200C 12 32V 20A AWG 10 IDC 200D 12 32V 20A AWG 10 IDC 200A 24 32V 10A AWG 16 IDC 200B 24 32V 10A AWG 16 IDC 200C 24 32V 10A AWG 16 IDC 200D 24 32V 10A AWG 16 IDC 200B 48 58V 4A AWG 22 IDC 200C 48 58V 4A AWG 22 5 88 58 175 4 168 0 H...

Page 4: ...ies which extend beyond those described herein This warranty is expressly in lieu of any other expressed or implied warranties including any implied warranty of merchantability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives There shall be no responsibility...

Reviews: