background image

6  |  SAMLEX AMERICA INC.    

 

3.  Layout of the EVO-4248SP

 

•   Refer to Section 2 of the Owner’s manual to become familiar with all the relevant 

connection points and components.

4.  Mounting the Units

 

•  Refer to mounting information at Section 3.3 starting at page 35 of the Owner’s Manual

 

•  Plan a safe location and routing of wiring for the associated components

 

•   The mounting surface should be able to support a weight of 3 times the weight of the 

inverter for 1 minute.  

 

•   Ensure that the mounting location is cool, dry and allows unobstructed air flow for cooling

 

•   Use 4 pcs of ¼”or M6 mounting bolts and washers. All dimensional information is 

shown in Fig 3.1 of the Owner’s Manual.

 

!

 CAUTION!

 

PLAN SYSTEM GROUND AND GROUND FAULT PROTECTION PRIOR TO INSTALLATION

 

 

  •   Ensure that the entire installation is properly grounded to meet Local and National Electrical Codes. 

 

 

  •   Refer to grounding at Fig 3.12 at page 53 of the Owner’s Manual.

 

 

  •  Ensure that the AC Neutral is bonded to the Earth Ground at only one point.

5.  Plan the Battery Bank

 

•   Select the type and size of the battery bank and bank configuration.  Refer to Section 3.4 

of the Owner’s Manual regarding installation of batteries.

 

•  Determine the overall Ah capacity (C) of the battery bank. 

 

•   Check with the battery manufacturer regarding maximum recommended charging 

current. The factory default “Bulk Current” parameter is set to 20A. 

 

•  Locate an appropriate area for the battery bank and cable routing to the EVO-4248SP.

 

•   The EVO-4248SP comes with a battery temperature sensor model EVO-BCTS. This 

sensor provides battery temperature information to the charging algorithm to ensure a 
proper and safe charge to the battery.  Refer to Section 2.5 of the Owner’s Manual.

 

•  An appropriately sized DC disconnect switch is recommended.

6.   Select and procure the appropriate wire size and lengths for the intended type of 

installation along with the appropriate breaker/fuse sizes

 

•   For sizing the AC input wiring and breakers, refer to Table 3.2 of the Owner’s Manual. 

 

•   For sizing the AC output wiring and breaker, refer to Table 3.3 of the Owner’s Manual.

 

•   For sizing the DC (Battery side) wiring and fuse, refer to Table 3.1 of the Owner’s Manual.  

7.    Determine whether the optional EVO-RC-PLUS remote control is necessary for 

your application

 

•   The Optional EVO-RC-PLUS Remote Control provides useful functional information such 

as battery voltage, battery charging status, and AC output power. EVO-RC-PLUS Remote 
Control is also capable of logging events to an SD card to create a history record of 
usage and performance.

EVO-4248SP INVERTER/CHARGER  |  

Quick Start Guide

Summary of Contents for Evolution EVO-4248SP

Page 1: ...Evolution TM Series Inverter Charger Pure Sine Wave Model EVO 4248SP Quick Start Guide...

Page 2: ...our specific needs 1 What s in the Box EVO BCTS EVO 4248SP 2 pieces 1 piece Mating Connectores Red Protection Covers Black EVO 4248SP EVO 4248SP Inverter Charger 1 EVO 4248SP Owner s Manual 1 EVO 4248...

Page 3: ...or 3 of the Owner s Manual that you do not understand do not attempt to install the unit yourself For a safe and code compliant installation consult a Certified Electrician who is familiar with Local...

Page 4: ...ER CHARGER Quick Start Guide Fig 1 Installation Diagram for Typical Shore Based Installation AC PANEL 1 N B G B G B SBJ DC AC DC AC SECTION Neg Bus 48V Battery Bank Pos Bus SBJ GEC GE AWG 6 AWG 6 DC E...

Page 5: ...tery Charger Temperature Sensor EVO BCTS 1 Battery Positive Input Connector 2 Battery Negative Input Connector 3 Positive Input Connector for External Charge Controller 4 Negative Input Connector for...

Page 6: ...capacity C of the battery bank Check with the battery manufacturer regarding maximum recommended charging current The factory default Bulk Current parameter is set to 20A Locate an appropriate area fo...

Page 7: ...s is recommended 8 You are now ready to install the EVO 4248SP Inverter Charger Re read Section 3 of the Owner s Manual Mount the EVO 4248SP in the planned location Mount cable and attach the optional...

Page 8: ...ns of Select Parameter Menu Maps Refer to EVO RC PLUS Manual Select Group Menu Map Fig 4 1 Column 1 Location of Select Parameter Menu Map Column 2 Location of TABLES for Parameter details Column 3 Gro...

Page 9: ...st you with installation setup and operating instructions For proper and safe installation of the unit consult a certified Electrician who is familiar with local and National Electrical codes CAUTION...

Page 10: ...10 SAMLEX AMERICA INC Notes...

Page 11: ...SAMLEX AMERICA INC 11 Notes...

Page 12: ...Fax 1 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouses Kent WA Plymouth MI Canadian Shipping Warehouse Delta BC Email purchase orders...

Reviews: