Samlex Solar SRV-100-30A Owner'S Manual Download Page 1

Please read this 
manual BEFORE  
operating 
your kit

Owner's 

Manual

Solar 

Charging Kit
SRV-100-30A
SRV-150-30A
SRV-200-30A

Summary of Contents for SRV-100-30A

Page 1: ...Please read this manual BEFORE operating your kit Owner s Manual Solar Charging Kit SRV 100 30A SRV 150 30A SRV 200 30A...

Page 2: ...ICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION 2 ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES DAMAGES COSTS OR EXPENSES WHETHER SPECIA...

Page 3: ...n 2 Make sure correct polarity is observed when making connections between the solar panel Charge Controller and the battery Damage due to reverse polarity connection is not covered by warranty 3 Make...

Page 4: ...s covered with an opaque dark material such as paper cloth during installation Do not make contact with the terminals when the panel is exposed to sunlight or any other light sources SECTION 2 Descrip...

Page 5: ...nocrystalline Polycrystalline Monocrystalline No of Cells 36 36 36 Maximum System Voltage UL 1703 600VDC IEC 61215 16730 1000VDC 1500V Series Fuse Rating 10A 15A 15A Terminal Box IP 65 with 2 Bypass D...

Page 6: ...x Stainless Steel Nylon Insert For Flange Bolt Srl 6 4 4 4 10 Well Nut Nut size 1 4 20 Length 1 Shank Dia 1 2 For fixing Mounting Bracket Srl 5 to RV roof other structure 4 4 4 11 Flange Bolt 1 4 20 x...

Page 7: ...IP67 Temperature range 40 C to 90 C MC4 Connectors Figs 3 1 3 2 The MC4 Connectors mentioned in this manual have been designated Male and Female based on the characteristics of the mating contact ins...

Page 8: ...cted in series to increase the output voltage will put out higher lethal voltages To avoid any electrical shock hazard during installation make sure that the solar panel array is covered with an opaqu...

Page 9: ...to the MC4 Female Connector marked that is attached to the Negative extension wire Make sure that the locking tabs snap in for a firm connection The bare end of the Negative PV Extension Wire will no...

Page 10: ...ig 3 5 To Charge Controller Female MC4 Connector Male MC4 Connector SCW 20 2 Kit SBC 2 Kit SCW 20 2 Kit MC4 Male Branch Connector MC4 Female Branch Connector MC4 2 Fig 3 5 Connecting two solar panels...

Page 11: ...the installation procedure 2 Open the packaging and check to make sure that all parts have been received as per the List of Components page 6 3 Arrange for the required tools to carry out the install...

Page 12: ...Charge Controller mark the cut out on the installation surface and the location of the mounting holes 8 Using a hand drill and suitable drill bit drill the mounting holes 9 Using a jig saw or suitable...

Page 13: ...that the mounting surface on the RV roof is strong enough to support the mounting hardware solar panel and wind loads 5 The centre and end holes on the mounting brackets Fig 7 2 are sized to accept t...

Page 14: ...Nuts drill holes 1 deep at the marked positions using a size drill bit Make sure that drilling does not interfere with pre existing wiring installations 8 Apply silicone or any appropriate sealant rec...

Page 15: ...l be required to be changed accordingly Use AWG 12 for up to 6 ft and AWG 10 for up to 10 ft to limit voltage drop to 3 at maximum 10A Use AWG 8 for up to 6 at a maximum current of 30A and 10 at 15A M...

Page 16: ...from the RV roof edges and leave sufficient space to walk around the panel and access the mounting hardware 2 Make sure the thickness of the roof at the installation location is at least thick and the...

Page 17: ...e Controller through the hole Use appropriate sealant as recommended by your local RV dealer to ensure the penetration at the side of the vent is watertight B Through the vent screen Route the wire pa...

Page 18: ...al of Battery 2 becomes the Negative terminal of the 12V battery bank Parallel Connection of Batteries Solar Charge Controller SCC 30AB rear view Solar Charge Controller SCC 30AB rear view PV PV BAT B...

Page 19: ...o the Solar Charge Controller SCC 30AB See Figs 9 2 and 9 3 given above attention should be paid to the manner in which the Solar Charge Controller is connected to the battery bank Please ensure that...

Page 20: ...ll be charged at different charging current and thus will reach fully charged state at different times The battery with lower series resistance will take shorter time to charge as compared to the batt...

Page 21: ...ous US and Canada only No refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to rem edy the defect after having a reasonable number of opportunities to do so...

Page 22: ...22 SAMLEX AMERICA INC NOTES...

Page 23: ...SAMLEX AMERICA INC 23 NOTES...

Page 24: ...ee Numbers Ph 1 800 561 5885 Fax 1 888 814 5210 Local Numbers Ph 604 525 3836 Fax 604 525 5221 Website www samlexamerica com USA Shipping Warehouses Kent WA Plymouth MI Canadian Shipping Warehouse Ric...

Page 25: ...Veuillez lire ce guide avant d utiliser votre trousse Guide de l Utilisateur La Trousse de Recharge Solaire SRV 100 30A SRV 150 30A SRV 200 30A...

Page 26: ...INENCE DE TOUTE TECHNIQUE OU D AUTRES INFORMATIONS FOURNIES DANS SES MANUELS OU D AUTRES DOCUMENTS 2 N ASSUME AUCUNE RESPONSABILIT OU RESPONSABILIT POUR LES PERTES DOMMAGES CO TS OU D PENSES QU IL S A...

Page 27: ...us que la bonne polarit est observ e lorsque vous branchez le panneau solaire le r gula teur de charge et la batterie Les dommages dus un inversement de la polarit ne sont pas couverts par la garantie...

Page 28: ...d lectrocution assurez vous que le panneau solaire soit recouvert d un mat riel opaque noir tel que du papier tissu lors de l installation Ne touchez pas les bornes lorsque le panneau est expos la lu...

Page 29: ...Cellules Monocryistallin Polycryistallin Monocryistallin No de Cellules 36 36 36 Tension Maximale du Syst me UL 1703 600VDC IEC 61215 16730 1000VDC 1500V Classification du Fusible en S ries 10A 15A 15...

Page 30: ...4 20 x po Hex Acier INOX pour la fixation du pannaeeau au support de Montage Srl 5 4 4 4 8 Rondelle Plate 1 4 INOX Sous le boulon Bride Srls 6 et 10 8 8 8 9 Contre crou po Hex Acier Inox encart en nyl...

Page 31: ...des fils sont termin es avec un type de connecteur accouplement sp cial pour faciliter l extension de ces fils pour des autres connexions Les connecteurs accouplement utilis s pour les 90 cm de fils...

Page 32: ...Insert 5 Snap in type of locking tabs that slide inside locking slots 2 of the mating MC4 Female Connector Fig 3 1 3 l encart d accouplement femelle 4 Des languettes de verrouillage enfichables pour...

Page 33: ...ur le fil photovolta que Positif Au Contr leur de Charge Connecteur MC4 Femelle d sign par Connecteur MC4 M le d sign par La Fig 3 3 Connexion des c bles d extension au c bles de sortie du panneau sol...

Page 34: ...e pour augmenter le courant de sortie la m me tension de sortie La Fig 6 5 ci dessus illustre l arrangement pour le raccordement de deux panneaux solaires en parall le l aide des fil de connexion SCW...

Page 35: ...e connexion SCW 20 2 2 ensembles un ensemble est fourni avec la trousse le deuxi me doit tre command s par ment Un connecteur ramifi MC4 M le et Un connecteur ramifi MC4 Femelle qui sont vendus s par...

Page 36: ...et chercher comprendre la proc dure d installation 2 Ouvrir l emballage et s assurer que toutes les pi ces ont t re ues selon la liste des pi ces dans le guide Page 5 3 Disposer des outils n cessaire...

Page 37: ...du R gulateur de Charge 1 La Trousse de Recharge Solaire Samlex est livr e avec un r gulateur de charge avec MLI de 30 A mod le no SCC 30AB qui vous permet de recharger vos batteries de mani re optima...

Page 38: ...rous de centre et d extr mit sur les supports de montage Fig 7 2 sont dimensionn s pour accepterles pi ces de fixation de po fourni avec l appareil Si l utilisation de pi ces de fixation de taille plu...

Page 39: ...marqu es Veiller se que le forage ne nuise pas au c blage existant 8 Appliquer g n reusement du silicone ou un produit d tanch it appropri recommand par le d taillant de votre VR aux trous perc s pou...

Page 40: ...s devront tre modifi es en cons quence Utilisez AWG 12 jusqu 6 pieds et AWG 10 jusqu 10 pieds pour limiter la chute de tension 3 un maximum de 10A Utilisez AWG 8 jusqu 6 un courant maximum de 30A et 1...

Page 41: ...s climatiseurs antennes de TV etc Autant que possible positionnez les panneaux afin de minimiser la longueur du c blage entre le panneau solaire et le r gulateur de charge Placez le panneau au moins 2...

Page 42: ...solaire et la surcharge du vent 7 Enlever le couvercle d a ration pour acc der l ouverture des conduits et garder les ferrures de fixation de l vent en toute s curit puisque le couvercle d a ration do...

Page 43: ...rie de 6V Batterie de 6V Cha ne 1 Cha ne 2 Batterie 1 Batterie 3 Batterie 2 Batterie 4 Batterie 1 Batterie 3 Batterie 2 Batterie 1 Batterie 2 Batterie 4 Cable A Cable B Cable A Cable B Cable A Cable B...

Page 44: ...sont branch es en s rie pour former une batterie de 12V 200 Ah Cha ne 1 De la m me fa on deux batteries de 6V 200 AH les Batteries 3 et 4 sont branch es en s rie pour former une banque de batteries d...

Page 45: ...l tement charg des moments diff rents La batterie avec une plus faible r sistance en s rie n cessitera moins de temps pour tre charg e par rapport la batterie qui voit une plus grande r sistance en s...

Page 46: ...chat sera accord l Acheteur moins que le Garant ne soit pas en mesure de rem dier au d faut apr s avoir b n fici d un nombre raisonnable d occasions pour ce faire Le service de garantie sera effectu u...

Page 47: ...SAMLEX AMERICA INC 23 NOTES...

Page 48: ...Sans Frais T l 1 800 561 5885 T l c 1 888 814 5210 Num ros locaux T l 604 525 3836 T l c 604 525 5221 Site internet www samlexamerica com Entrep ts USA Kent WA Plymouth MI Entrep t Canada Richmond BC...

Reviews: