4. This ring terminal should be mounted on a terminal post of a battery in
a bank.
• Switch off all devices operating from the battery
• Connect the ring terminal of the sensor (1, Fig 1) directly to the Negative
battery stud. This provides a very good thermal sensing of the battery as
well as preventing error in temperature sensing due to loss of contact
under vibrations
• Route the sensor cable to the charge controller
• Connect the Positive (+) bare end of the wire (2, Fig 1) to the Positive
terminal marked BTS + on the Charge Controller (Fig 2)
• Connect the Negative (-) bare end of the wire (3, Fig. 1) to the Negative
terminal marked BTS – on the Charge Controller
CAUTION!
Please ensure that the Positive wire is connected to the
POsITIve connector BTs+ and the negative wire is connected
to the NegATIve connector BTs–.