4. This ring terminal should be mounted on a terminal post of a battery in

a bank.

• Switch off all devices operating from the battery
• Connect the ring terminal of the sensor (1, Fig 1) directly to the Negative

battery stud. This provides a very good thermal sensing of the battery as
well as preventing error in temperature sensing due to loss of contact
under vibrations

• Route the sensor cable to the charge controller
• Connect the Positive (+) bare end of the wire (2, Fig 1) to the Positive

terminal marked BTS + on the Charge Controller (Fig 2)

• Connect the Negative (-) bare end of the wire (3, Fig. 1) to the Negative

terminal marked BTS –  on the Charge Controller

CAUTION! 

Please ensure that the Positive wire is connected to the  
POsITIve connector BTs+ and the negative wire is connected 
to the NegATIve connector BTs–.