
Use of the product
32
9.4
Shutdown procedure
Pump
To avoid the risk of personal injury, material injections,
injuries caused by moving parts or electric arcs, it is
imperative that the following procedure be followed
before any work is carried out when shutting down the
system, assembling, cleaning or changing the nozzle.
Lock the guns (valve, tap...) on OFF.
Shut off the air supply through the shut off valve to
remove residual air from the motor.
Unlock the gun (valve, tap...).
Bring the gun (valve, tap...) close to a metal
bucket in order to recover the product. Hold it
against the wall of the bucket to avoid
interrupting the grounding continuity (if necessary,
use the wire with clamp to ground the metal
bucket).
Open the gun (valve, tap) in order to drain the
circuit.
Lock the gun (valve, tap) on OFF position.
Open the pump drain valve and collect the fluid
in a properly grounded metal pail.
Leave the bleed valve open during the entire
operation.
Check the conformity of the wiring before intervention.