background image

Safety instructions 

13 

2.2

 

Integrity of the material  

 

Material recommendations 

 Protectors are put in place for safe use of the equipment.  

The manufacturer cannot be held responsible in case of: 

 

Bodily injury. 

 

As well as breakdowns and / or damage to the equipment 
resulting from the destruction, the misuse  or the total or 
partial withdrawal of the protectors. 

 

Pump 

It is imperative to be aware of the compatibility of the motors and 
pumps before coupling them together as well as the special safety 
instructions. These instructions can be found in the instruction manuals 
of the pumps. 
The air motor is intended to be coupled to a pump. Never modify the 
coupling system. Keep hands away from moving parts. The moving 
parts must be kept clean. Before commissioning or using the motor 
pump, read carefully the DECOMPRESSURIZATION PROCEDURE. Check 
the proper operation of the pressure relief and bleed air valves. 

 

Tubing 

Recommendations 

 

Keep hoses away from traffic areas, moving parts and hot 
areas. 

 

Never subject hoses being produced to temperatures 
above 80°C or below 0°C. 

 

Do not use hoses to pull or move equipment. 

 

Tighten all connections and hoses and couplings before 
operating equipment. 

 

Check hoses regularly and replace if damaged. 

 

Never exceed the maximum working pressure (MWP) stated 
on the hose. 

 

When fitting the hoses and the gun: PPE must be worn. 

 

Tighten to full stop (hoses + gun). 

 

 

Summary of Contents for REXSON 2B453

Page 1: ...L PUMP 453 cm3 Pump REX2B0453 User Manual 582134110 2021 09 15 Index C Translation of the original instructions SAMES KREMLIN SAS 13 Chemin de Malacher 38240 Meylan www sames kremlin com 33 0 4 76 41...

Page 2: ...y form whatsoever and any exploitation or communication of its contents are prohibited except with the express written consent of SAMES KREMLIN The descriptions and features contained in this document...

Page 3: ...NUMBERS OF HIGH VISCOSITY PUMPS 17 4 2 TABLE 1 FLUID SECTION AIR MOTOR SELECTION 18 4 3 TABLE 2 FLUID SECTION PUMP FOOT MATERIAL SELECTION 18 4 4 TABLE 3 SEALS PACK SELECTION 18 5 IDENTIFICATION 19 5...

Page 4: ...faults Causes of faults Remedies to apply 34 10 MAINTENANCE 36 10 1 PREVENTIVE MAINTENANCE PLAN 37 Fluid section 37 10 2 GENERAL PRECONISATION MAINTENANCE 38 11 DISASSEMBLY REASSEMBLY OPERATION 39 Gre...

Page 5: ...sed your new equipment and we thank you for it We have taken the utmost care from design to manufacture so that this equipment gives you complete satisfaction For a good use and an optimal availabilit...

Page 6: ...iate The warranty excludes wear parts deterioration or wear resulting from abnormal or unscheduled use by SAMES KREMLIN failure to observe instructions for proper operation or lack of maintenance The...

Page 7: ...Declaration of Conformity 7 1 Declaration of Conformity Refer to the existing declaration delivered with the product...

Page 8: ...cause serious injury This material is for professional use only It must be used only for the purpose for which it was intended Do not modify or transform the material Parts and accessories must only b...

Page 9: ...on Danger hot parts or surfaces Danger flammability risks Danger electricity Risk of explosion Danger user Warning Danger Gloves required Grounding Protective helmet Hearing pro tection Mandatory resp...

Page 10: ...components Danger of pressure Safety requires that a pressure relieve shutoff valve be mounted on the pump motor supply circuit to allow trapped air to escape when the supply is shut off Without this...

Page 11: ...g insufficient ventilation open flames or sparks can cause an explosion or fire which could result in serious injury To avoid these risks especially when using pumps it is imperative Before operating...

Page 12: ...n the application in a container designed for that purpose Treat product waste with the legislation of the country where the equipment is used To wear protective clothing designed for that purpose Wea...

Page 13: ...r motor is intended to be coupled to a pump Never modify the coupling system Keep hands away from moving parts The moving parts must be kept clean Before commissioning or using the motor pump read car...

Page 14: ...erent risks to staff and the environment Wear and tear maladjustment malfunction of equipment or machines and the quality of the finished product The user will have to identify and prevent the potenti...

Page 15: ...be earthed via the earth cable of this motor This earth cable must be connected to a safe earth ground Have the earth ground continuity checked by a qualified electrician If the ground continuity is...

Page 16: ...designed and manufactured with high quality materials and components that can be recycled and reused European Directive 2012 19 EU applies to all devices marked with this logo crossed out bin Find out...

Page 17: ...cts 50000 cP Different configurations are available Significant designation Ex 1 cP 1 mPa s 2B R E X 0453 Technology Ball pump 2B Air Motor None XX Motor 7200 72 Motor 9200 92 Refer table 1 Material o...

Page 18: ...Available foot pump Available material CS Mixed materials WM Wall mounted FP Follower plate 4 4 Table 3 Seals Pack Selection Available Seals Packing Static seals O rings Upper seals packing Piston se...

Page 19: ...Voltage Directive 2006 95 EEC EMV Directive 2004 108 EEC Safety of machinery Basic terms general implementation guidelines DIN EN ISO 12100 T1 T2 Safety of machinery Temperatures of touchable surfaces...

Page 20: ...pressure Bar Psi AIR Maximum air pressure Bar Psi RAPPORT RATIO Pump pressure ratio CE EC European conformity II2G Use in explosive area II group II 2 category 2 Surface material intended for an envi...

Page 21: ...nificant Designation 61 MO 0453 M S F 000 REX2B0453 MO MA FO SE Options MO Motor MO 55 MOT7200 72 56 MOT9200 92 M Material MA 1 Mixed Steels CS S Seal SE 3 PE PTFE G 03 6 PU 06 F Foot FO 1 Wall mounte...

Page 22: ...Seal 102 724 REX2B0453 92 CS WM 06 MOT9200 65 1 CS Mixed Steels WM Wall mounted 06 PU PTFE G 102 724 01 01 REX2B0453 XX CS WM 06 None CS Mixed Steels WM Wall mounted 06 PU PTFE G 47 222 724 REX2B0453...

Page 23: ...g on Materials of construction and seals kit Packings Depending on seal kit Available Motors Motor selection XX 72 92 NONE MOTOR 7200 MOTOR 9200 Pressure Ratio 40 1 65 1 Maximum Air Inlet Pressure bar...

Page 24: ...105 mm Materials of construction CS Mixed materials Pump body Wet Cup Carbon steel Upper body Carbon steel Cylinder Stainless steel chromed Piston Upper check Piston rod Carbon steel Valve body Carbon...

Page 25: ...flap 2 closes and the lower flap 3 opens The piston 1 expels the product from the upper chamber V2 to the outside and sucks the product to fill the lower chamber V1 When the piston 1 is lowered the up...

Page 26: ...ment of the product inside the pump and its accessories as well as that caused by the seals creates static electricity that can cause fire or explosion Therefore the fluid section system must be earth...

Page 27: ...order in which the cables hoses and pipes are connected is in accordance with the connection diagram Make sure that all cable connectors hose and pipe connections are correctly fitted Remember that u...

Page 28: ...ure drops 7 3 Storage Pump Place the equipment away from moisture after closing the various air inlets and various openings plugs Storage before installation Storage ambient temperature 0 50 C Protect...

Page 29: ...removed by flushing with a suitable solvent At the end of the day flush with a suitable solvent It is advisable to stop the fluid section in the low position in order to prevent the product from takin...

Page 30: ...ening Tightening of the Wet Cup Verify cup is filled with lubricant T Run the pump then tighten the cup after 10 minutes again after 1 hour then after1 day of operation In the event of a leak the cup...

Page 31: ...pump is mainly dedicated to the transfer and application of viscous products the pin is when leaving the factory positioned at the highest point This allows the ball to move far away from the seat and...

Page 32: ...ulting from the destruction the occultation or the total or partial removal of the protectors 9 3 Start up Pumps are tested for operation at the factory using a light weight oil lubricant Before commi...

Page 33: ...off valve to remove residual air from the motor Unlock the gun valve tap Bring the gun valve tap close to a metal bucket in order to recover the product Hold it against the wall of the bucket to avoid...

Page 34: ...stopped The fluid is polymerized hardened dried in the pump Clean the pump change the parts if necessary The cup is too tightened Loosen Broken part s in the pump Remove check replace The motor seems...

Page 35: ...s incorrectly mounted or damaged Check the mounting change if necessary The pump does not deliver enough pressure Insufficient air pressure to the motor valve insufficiently open air leak Check adjust...

Page 36: ...only the most common problems If the information given here does not solve the problem you are experiencing please contact your local SAMES KREMLIN representative for assistance During prolonged shut...

Page 37: ...Check the condition of the hoses Observe the piston rod of the pump Do not let the product dry onto the piston rod Check the lubricant level inside the cup keep it at half level Fill it if necessary...

Page 38: ...d it is imperative to follow the depressurization procedure and the safety instructions Before each reassembly Clean the parts with the appropriate cleaning solvent Fit new seals if necessary after gr...

Page 39: ...does not engage our responsibility Before each reassembly Clean the parts with appropriate cleaning solvent Fit new seals if necessary after greasing them Grease the piston and the inside of the cyli...

Page 40: ...bly operation 40 Fluid section follower plate wall mounted with seals pack 03 REX2B0453 FP 03 REX2B0453 WM 03 For a full description of spare parts see Part 12 Spare Parts A 2 A 1 A 1 A 1 A 2 A 1 A 1...

Page 41: ...bly operation 41 Fluid section follower plate wall mounted with seals pack 06 REX2B0453 FP 06 REX2B0453 WM 06 For a full description of spare parts see Part 12 Spare Parts A 2 A 1 A 1 A 1 A 2 A 1 A 1...

Page 42: ...the fluid section model REX2B0453 FP the flange 31 and the O Ring 29 Take off the piston 15 downwards Put aside the cylinder 10 Lower valve Unscrew the body of the filling body 26 Take off the valve...

Page 43: ...ng 7c Clean the parts check them if they are damaged or worn change them Reinstall the parts in the reverse order of the disassembly sequence For the fluid section model REX2B0453 06 Unscrew the wet c...

Page 44: ...here are damaged or worn change them Reinstall the parts in the reverse order of the disassembly sequence Reassembly of the fluid section Lubricate the cup seals and piston rod seals Slide the piston...

Page 45: ...ssories and spare parts designed to withstand the pump s operating pressures Fluid section follower plate wall mounted with seals pack 03 REX2B0453 FP 03 REX2B0453 WM 03 WARNING these parts are not su...

Page 46: ...pare parts 46 Fluid section follower plate wall mounted with seals pack 06 REX2B0453 FP 06 REX2B0453 WM 06 WARNING these parts are not supplied with the fluid section alone as they depend on the engin...

Page 47: ...1 2 12 M washer 84 180 1 1 13 Pin See motor coupling kit table 2 3 14 Tie rod See motor coupling kit table 4 3 15 Piston rod 205 735 1 2 16 Lock nut 88 338 4 3 17 Ball 86 028 1 2 18 Piston bush 205 7...

Page 48: ...N S 209 582 2 4 Protective housing N S 208 236 1 14 Tie rod N S 203 169 4 Recommended maintenance parts N S Denotes parts are not serviceable Level 1 Preventive maintenance Level 2 Corrective mainten...

Page 49: ...E 9 O Ring 2 909 420 249 FKM 2 909 420 249 FKM 20 M washer 2 205 768 PE 27 Spacer 1 207 501 1 207 501 Cup packing 7 210 587 PE 4 1 84 333 210 587 PU PE Piston packing 7 207 499 PTFE G 7 207 499 PTFE G...