SAMES KREMLIN
- 4 -
N° : 578.067.120-UK-1903
3. INSTALLATION
The pumps are designed to be installed in a spray booth.
DESCRIPTION OF THE LABEL MARKING
Marking in accordance with
the ATEX regulation
SAMES KREMLIN
STAINS FRANCE
Name and address of the manufacturer
TYPE xx
Pump model
CE
II 2 G
CE
: European conformity
:
For use in explosive area
II
: group II
2
: class 2
G
: gas
Surface equipment meant to an area where explosive atmospheres due to
gas, vapours, mists are liable to appear from time to time in usual operating.
P prod : xx bar / xx psi
Maximum fluid pressure at the pump outlet
P air : 6 bar / 87 psi
Air supply maximum pressure of the pump motor
Serie / Serial
Number given by SAMES KREMLIN. The 2 first numbers indicate the
manufacturing year.
TEMPERATURE CLASS
Pumps, model 08C240 & 08C240 T:
Temperature class
Maximum surface temperature
T2
273°C / 523.4°F
Pumps, model 16C240 & 16C240 T :
Temperature class
Maximum surface temperature
T2