8
4
Identification of the product
4.1
Description of FSTART Gravity
Guns recommended to spray varnishes, lacquers, shades, polyurethanes.
4.2
Description of the ATEX marking
•
Each device is marked with the name of the manufacturer, the reference of
the device and important information for the use of the device (air pressure,
electrical power, etc.).
•
This equipment has been designed in accordance with the ATEX Directive
2014/34/EU and is intended for use in Zone 1.
SAMES KREMLIN
FRANCE
Name and address of the manufacturer
CE
II 2 G
CE
: European conformity
:
for use in explosive
area
II
: group II
2
: class 2
G:
gas
Surface equipment meant to an area where
explosive atmospheres due to gas, vapours, mists
are liable to appear from time to time in usual
operating.
On the body
Ex h IIB T6 X
Ex
:
Marking of conformity with European standards
h
:
Mode of protection for non-electrical device
IIB
:
Gas group
T6
:
Temperature class
- Maximum surface temperature : 85°C / 185° F
X :
Special conditions that apply for a safe use.
Refer to instructions listed in the instruction manuals
accompanying your purchase.
Gb
Gb
:
Equipment protection level (Gas zone1)
20xx
Marking of the manufacturing year (with 4
characters)
FSTART
Type xx
Gun model
P air : 6 bar / 87 psi
Gun air supply maximum pressure