Doc.-ID: 200917-PT08BA-ES-ExCam IPP1275_en_rev.00.docx, Page 12 of 28
Wiring table:
Potential
Colour (IEC 60757)
Cross-
section
Comment
PA
GN/YE
4 mm
2
(rigid)
Terminal: Slotted screw M3x0.5 (DIN 84) with
washer Ø9mm (DIN 125A),
Keep 1.2 Nm tightening torque!
Table 5-1 Potential equalization
5.2
Connection work at the device (terminal box) and fuses
Power supply for the camera (PoE)
Voltage supply:
PoE, IEEE 802.3af/802.3at type 1 class 2
Reference voltage:
+4 V DC
Maximum power consumption:
4.0 W
Typical power consumption:
2.5 W
The figures 5.2 and 5.3 illustrate the potential cable terminations of the ExCam IPP1275.
Possible terminations are sensor unit connected to an ExConnection Rail (T08-
…-TD) or
sensor unit with RJ12 plug and main unit P12 MkII for safe areas (T08-
…-P).
Figure 5-2 ExCam IPP1275 T08-VA0.1.K1.BOR-N.N-xxx.N-
P
Figure 5-3 ExCam IPP1275 T08-VA0.1.K1.BOR-N.N-xxx.N-
TD
not included