AIS 3410, Electronics Unit
ED3047G842 / 01 (2009-08)
Technical Manual
6 Repair/Maintenance
6.1 Trouble Shooting
t_ue_e07.fm / 27.08.09
50
2.
Connect the AIS output TB14 and TB15 of the Analog Interface additionally to an indicator serial
interface (TB1) of the radar. If there is a free input, this one should be used. If all inputs are used,
one of them must be disconnected.
shows the connection to the serial interface No. 4 as
an example.
Fig. 6-1
Cable connection for the interface monitoring Radar > AIS
3.
Power on the radar. Configure the concerned indicator serial interface by means of the System Main-
tenance Manager as follows
Path:
Configure
>
Radar
>
Indicator
>
Indicator x
>
Serial Interfaces
>
Serial I/O x
Parameters:
-
Driver
, set to
NMEA183 (IEC 61162-1/2)
-
Baud Rate
, set to
38400
-
Wind
, set to
Connected
(if the interface has been used for a ship’s sensor with NMEA183
(IEC 61162-1/2) protocol beforehand, it is not necessary to modify this parameter.)
4.
The Serial I/O Monitor must be started.
Path:
Service
>
Indicator
>
Serial I/O Monitor
Select the used interface from the drop down list and mark the check box
Rx
. Start the monitoring
by clicking on
Run
. The protocol can be saved on a diskette.
z_u
e_0
25
.pd
f
An
a
log Interf
a
ce
Interconnection Bo
a
rd
RADARPILOT/CHARTRADAR
MULTIPILOT 1000/1100
AI
S
Electronic
s
Unit
Primary Di
s
play Port
8
10
16
O
u
tp
u
t -
AI
S
RxD, Inp
u
t -
RxD4, Inp
u
t +
O
u
tp
u
t +
AI
S
RxD, Inp
u
t +
RxD4, Inp
u
t -
Inp
u
t -
AI
S
TxD, O
u
tp
u
t -
Inp
u
t +
GND
AI
S
TxD, O
u
tp
u
t +
GND
Connector 2
TB
TB1 Indic
a
tor
S
eri
a
l Interf
a
ce 4
6
14
5
1
15
16
7
11
17