SALZ 2016GT Quick Installation Manual Download Page 2

-4-

-5-

-6-

To insert power wire and connect the 12 to 60 V DC at a 

maximum of 1.5 A DC power to the power terminal block, follow 

the steps below:

•  Use flat-head screw driver to loosen the wire-clamp screws
•  Insert the negative/positive DC wires into the PWR-/PWR+ 

terminals, respectively

•  Tighten the wire-clamp screws to prevent the wires from loosen-

ing

!

ATTENTION:  

Please use a power supply from 12 to 60 V DC, the 

device power shall be supplied by SELV circuit.

!

ATTENTION:  

This device complies with Part 15 of the FCC rules. 

Operation is subject to the following conditions: 

1. This device may not cause harmful interference

2. This device must accept any interference received  

  including interference that may cause undesired  

 operation

!

ATTENTION:  

If the equipment is used in a manner not specified by 

SALZ Automation, the protection provided by the 

equipment may be impaired.

Connect one end of an Ethernet/RJ45 cable into Ethernet port 

of SWITCH 2016GT and other end to attached networking 

device. 
•  Ports 1-16 of the switch support Fast Ethernet as well as 

Gigabit Ethernet (10/100/1000Base-T RJ45 Ports)
•  All the RJ45 ports on the SWITCH 2016GT support auto 

negotiation and auto MDI/MDI-X to eliminate the need for 

crossover cabling

5.3 Cabling RJ45

Address of the manufacturer:
SALZ Automation GmbH
Max-Planck-Str. 64
32107 Bad Salzuflen, Germany 
Email: [email protected]

Please scan for more information:

v0.2

Note: Category 5e cable or above should be used.

Operating Temperature

-40˚C ... 70˚C

Storage Temperature

-40˚C ... 85˚C

Altitude 

Up to 2000m

Ambient relative humidity

5 to 95% (non-condensing)

UL61010

Indoor use and pollution degree 2 

6. DIP Switch Setting

8. Environmental limits

7. LED Indicators

PWR

(Green)

Power On by terminal block PWR or 

DC-Jack
Terminal block PWR/DC-Jack fails or 

is not available

RPS

(Green)

Power On by terminal block RPS
Terminal block RPS fails or is not available
PWR/RPS fails or not available
No alarm

LNK/ACT

(Green)

Copper port link-up 1000Mbps
Data is transmitting / receiving
Port disconnected or link failed

Illuminated

Illuminated

Illuminated

ALM

(Red)

1000M

(Green)

Off

Off

Off

Illuminated

Off

Illuminated

Blinking

Off

Link speed at 10/100Mbps

Link speed at 1000Mbps

The SWITCH 2016GT has one set of relay alarm output. This 

relay contact uses two contacts of the terminal block on the  

top panel.
The two contacts of the 6-pin terminal block connector are 

used to detect user-configured events. The two wires attached 

to the fault contacts form an open circuit when a user-config-

ured event is triggered. If a user-configured event does not 

occur, the fault circuit remains closed.
Relay rating: 24V, 1A

5.2 Wiring the relay contact (ALM)

ON  : Primary power alarm reporting is enabled
OFF  :  Primary power alarm reporting is disabled
ON  :  Redundant power alarm reporting is enabled
OFF  :  Redundant power alarm reporting is disabled

ON

OFF

ON

PWR 

RPS

PWR
RPS

Load

External

Power