en
55 / 108
7.3.2
Changing the time and the setpoint temperature for the current frying process
The time and the setpoint temperature cannot be changed while the short time clock runs down.
The performed temperature change is cancelled after
−
a different temperature key is pressed,
−
the appliance is switched off and on at the "On/Off" key, or
−
the appliance is switched off and on at the customer's electrical main switch.
To adjust the time and setpoint temperature set at the factory to your requirements and permanently store
these changes, follow the procedure described on page and following in 56 chapter 7.5.
Changing the time / setpoint temperature for the current frying process
Press the "P" key.
The time flashes on the left display.
If you wish to change it, press and hold down the "up"
or "down" key
within 3 seconds.
First, the values are reduced or increased slowly, then rapidly. By pressing the key, the setting is re
duced or increased by one step respectively.
Press the "P" key.
The changed time has been stored.
The setpoint temperature flashes on the right display.
If you wish to change it, press and hold down the "up"
or "down" key
within 3 seconds.
First, the values are reduced or increased slowly, then rapidly. By pressing the key, the setting is redu
ced or increased by one step respectively.
To save the settings - Press the "P" key or wait for approx. 3 seconds.
7.4
Displaying the actual temperature in the bowl
When the appliance is switched on, press the "temperature/pump"
key.
Two temperatures are displayed for 3 seconds:
−
Actual temperature on the left display and
−
setpoint temperature on the right display.
-
3 sec.
3 sec.
Operating mode "Product keys"