en
23 / 56
4.2
Cleaning the stainless-steel surfaces
.
If aggressive cleansers have been used, thoroughly wipe down the cleaned components and
surfaces with a clean, damp dish cloth, without the use of a cleaning agent.
.
Clean all stainless-steel surfaces with fat-dissolving cleaning agents or special stainless-
steel care agents.
.
Rub the cleaned parts and surfaces dry with a soft cloth.
5.
Malfunctions and Rectification
Should malfunctions occur with the device, please check them with the help of the followingta
ble:
Malfunction
Cause
Rectification
The pilot light cannot be lit.
The gas tap is closed.
Open the gas tap.
The service valve is closed.
Open the service valve.
The pilot burner is contamin
ated.
inform the customer service.
The thermal element is contam
inated.
inform the customer service.
The pilot light is extin
guished upon the gas gov
ernor's release.
The gas governor was not
pressed in long enough.
Keep the gas governor pressed
for approx. 5 - 10 seconds to
assure the thermal element's
sufficient heating and avoid an
interruption of the gas supply.
The thermal element is defect
ive.
inform the customer service.
Should you not be able to rectify the malfunction,
- Switch the device off.
- Close the gas tap.
Close
Open
- do not open the housing,
- inform the customer service.