Temperature setting

Programming

Manual mode - temperature settings

NSB function - automatic mode

Installer settings

Error codes

dxx

Function

Value

Description

Default 

value

d01

Control method

temperature

0

PWM algorithm

0

1

Span ±0.5°C

2

Span ±1.0°C

d02

Offset temperature

from -3.0°C  

to +3.0°C

If the thermostat indicates 

wrong temperature, you 

can correct it by ± 3.0°C

0°C

d03

Using a floor tempera-

ture sensor (S1, S2)

0

No sensor

0

1

Sensor is connected

d04

External sensor

used for air  

or floor temperature 

measurement 

(Function is active,

when d03=1)

0

Thermostat measures the 

temperature only on the 

external sensor

0

1

The sensor is used  

as a protection against 

overheating the floor

d05

Cooling mode control 

method

1

Span ±0.5°C

2

2

Span ±1.0°C

d06

Type of thermoelectric 

actuator

0

NO - normally open

1

1

NC - normally closed

d07

Valve protection

0

OFF

1

1

ON

d08

Frost protection 

temperature

5-17°C

Frost protection / Holiday 

mode temperature 

5°C

d09

Clock format

0

12 hour

1

1

24 hour

d11

Daylight Saving Time

0

OFF

1

1

ON

d12

Heating temperature 

limit

5-35°C

The maximum heating 

temperature that can be set 

by the user

35°C

d13

Cooling temperature 

limit

5-40°C

The minimum cooling 

temperature that can  

be set by the user

5°C

d14

Maximum floor 

temperature 

(this function is active 

in heating mode when 

d04 = 1)

6-45°C

In order to protect the floor 

from overheating, heating 

will be turned OFF, when the 

maximum temp. of the floor 

sensor will be reached

27°C

d15

Minimum floor 

temperature

(this function is active 

in heating mode when 

d04 = 1)

6-45°C

In order to protect  

the floor, heating will 

be turned ON, when the 

minimum temp. of the floor 

sensor will be reached

10°C

d16

Lower floor temperature 

limit for cooling 

(this function is active 

when d04 = 1)

6-45°C

In order to protect the floor, 

cooling will  

be turned OFF, when  

the minimum temp. will 

be reached

6°C

d17

Choice of the default

program

1-5

Selection 1 of the 5 default 

programs

1

d18

Operating mode 

HEATING / COOLING

0

Heating system

0

1

Cooling system

Error code

Description

Err02

The maximum / minimum floor temperature has been exceeded

Err03

Temperature sensor is faulty

Err04

Temperature sensor is shorted

1

4

 3 sek.

 3 sek.

 3 sek.

Set the temperature  

with           or           buttons.

Select the service parameter 

using        or       buttons.

The parameter value 

is set by             or            . 

Press             to confirm the changes.

Press           to confirm the changes.

Press            to confirm the changes.

Current temperature.

Temperature set in the selected 

operating mode

Select the automatic mode 

using         or        buttons.

Press any button to highlight the screen, then follow the steps below:

Press any button to highlight the screen, then follow the steps below:

Thermostat also has 2 additional modes:

The NSB (Night SetBack) function can automatically change temperatures 

on VS35 daily thermostats via VS30 programmable thermostat connected to 

a wiring centre (or another external clock). NSB function switches between 

comfortable temperature           and economic temperature          .

To activate the automatic mode, select the           icon. On display together with 

the            icon, the controller indicates  active temperature mode:           or          .

- Comfort mode

- Standard mode

- Economic mode (when this mode is selected on the NSB output  

   appears 230 V AC voltage)

- PARTY mode sets the comfort temperature           for a defined time  

   by the user (maximum 9 hours 50 minutes).

- The HOLIDAY mode sets the frost protection temperature          for a user  

   defined period of time (maximum 99 days).

- Frost protection mode. Usually used in a longer period of absence  

   or during the holidays (available only in heating mode).

Press any button to highlight the screen, then follow the steps below:

Note: 

For the NSB function to work, it is necessary to connect the wirings 

properly. Connection diagrams can be found on the previous page.

2

3

Note: 

To restore the 

thermostat’s factory settings

, in step 2 set the PSuu  

to 

47

 code, and confirm the selection with the            button.

2

1

1

1

3

5

7

4

6

8

 3 sek.

Press any button to highlight the screen, then follow the steps below:

2

9

11

10

Use      button to choose days 

range for schedule:

Wybierz tryb pracy.

Set the program start time:

Repeat steps 5 - 10 to set time 

and temperatures for next time 

ranges. No hour (--:--) on the 

display means whole day  

is planned already.  

Schedule can be divided into 

maximum 6 time ranges.

- whole week

- weekdays

- weekends

- each day separately

There are 4 temperature levels available. In manual mode only one temperature 

level is active (icon in the frame              indicates which mode is currently chosen). 

For each temperature levels you can set a different temperature.

Press any button to highlight the screen, then follow the steps below:

Choose the temperature mode 

using       or       buttons.

2

1

2

3

4