Salus SC428ZW Installation & User Manual Download Page 2

Events

Association Group

Using association group, the Smart Plug is able to command or notify another device 
of a Z-Wave® network.

Group

Group Name

1

Lifeline

2

Follow State

3

Follow Complementary State

4

Metering - High Threshold-Set On/Off

5

Metering - Low Threshold-Set On/Off

SMC-QG-SC428ZW-202101v1

Z-Wave User Configuration

 

Parameter

Description

Values

Size 

Byte)

Default

1

Status when 

powered up

0 = Off 

1 = On 

2 = Status when last powered

1

2

3

Enable/

Disable for 

Group 2 & 3

0 = Group 2 & 3 disabled 

1 = Group 2 enabled 

2 = Group 3 enabled 

3 = Group 2 & 3 enabled

1

3

5

Overvoltage 

Alarm (V)

1-200 = Overvoltage Alarm threshold

2

132

6

Overcurrent 

Alarm (mA)

1-15000 = Overcurrent Alarm threshold

2

15000

21

Power 

Change 

Report

1 - 100 = % Power Change to Send Report

1

10

22

Overload 

Power Re-

port

1 – 1980 = 1 to 1980W

2

1980

23

Energy 

Report

1 – 327 = 1 KWh to 327 KWh

2

1

24

Metering 

Report

30 – 32767 = 30 – 32767 seconds to send report

2

3600

25

High Power 

Threshold

0 = High Power Threshold disabled 

1 – 32767 = High Power Threshold (Watts)

2

1980

26

Low Power 

Threshold

0 = Low Power Threshold disabled 

1 – 32767 = High Power Threshold (Watts)

2

5

27

Power 

Threshold 

Action

1 = Power Threshold Action disabled 

2 = Power High Threshold is enabled and send OFF 

       to group 4 

4 = Power High Threshold is enabled and send ON  

       to group 4 

8 = Power Low Threshold is enabled and send OFF 

       to group 5 

16 = Power Low Threshold is enabled and send ON 

      to group 5 

12 = 4 AND 8

1

12

User Event

Notification Type

Notification Event

Overvoltage 

threshold is met

Power Management 

(0x08)

Overvoltage Detected 

(0x07)

Overcurrent 

threshold is met

Power Management 

(0x08)

Overcurrent Detected 

(0x06)

Overload  

threshold is met

Power Management 

(0x08)

Overload Detected 

(0x08)

Group 1 - Lifeline 

Maximum number of devices in group: 5 

This group is generally used to report information of the Smart Plug to the Main 

Controller of the network, including Meter, Binary Switch Report, Notification and 
Device Reset Locally. 

Group 2 - Follow State 

Maximum number of devices in group: 5 

When the Smart Plug is switched ON (respectively OFF) using the local button, 

it will send ON (respectively OFF) command to the associated devices. No 

command is sent if the Smart Plug is switched ON or OFF wirelessly. This group is 
configurable through the parameter 3.

 

Group 3 - Follow Complementary State 

Maximum number of devices in group: 5 

When the Smart Plug is switched ON (respectively OFF) using the local button, 

it will send OFF (respectively ON) command to the associated devices. No 

command is sent if the Smart Plug is switched ON or OFF wirelessly. This group is 
configurable through the parameter 3.

 

Group 4 - Metering - High Threshold - Set On/Off 

Maximum number of devices in group: 5 

When the Smart Plug reaches over the high threshold of power defined by the 

configuration parameter, it will send OFF or ON command to the associated 

devices. This group is configurable through the parameters 
25 and 27.

 

Group 5 - Metering - Low Threshold - Set On/Off 

Maximum number of devices in group: 5 

When the Smart Plug reaches below the low  threshold of power defined by 

the configuration parameter, it will send OFF or ON command to the associated 

devices. This group is configurable through the parameters 

26 and 27.

Z-Wave Related Configuration

Specific Configuration Role Type:
Role Type: 
•  Always On Slave (AOS)
•  Device Type: BINARY_SWITCH
•  Supported security keys: S2
•  Unauthenticated
Library: 
•  Generic Type: SWITCH_BINARY
•  Specific Type: POWER_SWITCH_BINARY

Z-Wave Command Class Support

ZWAVEPLUS_INFO V2 

CONFIGURATION V1

TRANSPORT_ SERVICE V2 

BASIC V2 (Control and Support)

MANUFACTURER_SPECIFIC V2  VERSION V3 - ASSOCIATION V2
DEVICE_RESET_LOCALLY V1 

ASSOCIATION_GRP_INFO V3

SECURITY_2 V1 

 

SUPERVISION V1

POWERLEVEL v1 

 

FIRMWARE_UPDATE_META_DATA V4

BINARY_SWITCH V1   

PROTECTION V2

METER V4   

 

MULTI_CHANNEL_ASSOCIATION V3

Notification V8

Reviews: