Wireless Receiver Unit
Models: RX10RF
1 x Installer / User manual
Boiler Receiver x 1
2 x Screws
& 2 x Wall Plugs
For PDF Installation guide please go to
www.salus-controls.com
230V AC
Warning
Always isolate the AC Mains supply before installing or working on any components that
require 230 VAC 50Hz supply.
Sources of danger
The RX10RF must be disconnected from mains supply before removing the cover.
Emergency
Switch off the voltage to the individual thermostat wring centre or complete system.
Warning
This product must be fitted by a competent person, and installation must comply with
the guidance, standards and regulations applicable to the city, country or state where
the product is installed. Failure to comply with the requirements of the relevant guidance,
standards and regulations could lead to injury, death or prosecution.
INTRODUCTION
Thank you for purchasing the SALUS RX10RF system receiver. This unit is designed to work with
iT600 range of Zigbee network products.
The RX10RF can be configured as remote boiler switch or a simple single channel output to
control, a thermal actuator or zone valve. Please note the two configuratons above can be used
together in the one system.
These instructions are applicable to the SALUS model stated on the front cover of this manual only.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magnetic Compatibility directive 2004/108/EC
Low voltage Directive 2006/95/EC.
The unit can be switched internally switched to be used on two channels, RX1
(boiler receiver) or RX2 (single room receiver). Ensure the unit is not powered
during setting of the RX1/RX2 slide switch.
The unit is supplied with the switch in the RX1 position (Boiler
Receiver). In this mode, the unit can be wired to the boiler to
switch it on or off using the wireless signals it receives other
SALUS products on the SALUS Zigbee network
With the unit switched to RX2, the unit will act as a single room receiver. Switching
of the unit will be controlled by a paired SALUS VS10/20RF Thermostat. Depending
on its intended use, the unit can be used to switch a motorised valve, thermal
actuator or pump.
As well as being used in this way, the RX2 can be used in
conjunction with another unit set up as an RX1 (Boiler
receiver). When there is a call for heat from the thermostat
paired to the RX2 both of the wireless receivers will operate
turning on both the boiler and the motorised valve / pump.
NB: Only 1 RX1 and 1 RX2 can be used as part of a network.
*System Receiver configured
to boiler receiver. RX1
RX10RF configured
as Boiler Receiver RX1.
**System Receiver configured
to one room receiver RX2.
Max 3 TRV per thermostat
RX1
UNDERFLOOR HEATING MANIFOLD
System Receiver configured to boiler receiver RX1.
Refer to reverse side for wiring.
System receiver configured as stand alone receiver
RX2. Refer to reverse side for wiring.
RX1 & RX2 RECEIVER CONFIGURATION
The receiver can be configured as a Boiler Receiver (RX1) where
it will react to signals from a large number of components such
as SALUS wireless wiring centres, wireless thermostats used
with SALUS wireless radiator valves as well as another receiver
configured as a Stand Alone receiver (RX2).
RX10RFX Configured
as Stand Alone
receiver RX2.
1
2
3
4
User Interface
iT600 System
AUTO – System receiver output will
switch on and off in relation to the
command from the iT600 transmitter.
The bottom slide switch in active
RED led only in AUTO means that there
is no output from the receiver.
RED and Green LED only in AUTO
means that there is an output from the
receiver. The device that the receiver is
connected to will be switched on.
Manual- system receiver output is
controlled by the bottom slide switch.
Either permenetly ON or OFF. The LED
status in manual is the same as AUTO.
VS10/20RF
RX10RF*
CO10RF
RX10RF**
VS10/20RF
KL10RF