I N S TA L L E R / U S E R M A N U A L
Wireless Receiver Unit
Models: RX10RF
www.salus-controls.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES:
T: +44 (0) 1226 323961
TECHNICAL:
T: +44 (0) 1226 323961
For PDF Installation guide please go to
www.salus-controls.com
Maintaining a policy of continuous product development SALUS
Controls plc reserve the right to change specification, design and
materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
00086/2 Issue Date: June 2014
SALUS Controls warrants that this product will be free from any defect in materials or workmanship,
and shall perform in accordance with its specification, for a period of five years from the date of
installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair
or replace the defective product.
Customer Name: ..........................................................................................................
Customer Address: .......................................................................................................
................................................................ Post Code: ...................................................
Tel No: .................................................... Email: ..........................................................
Engineers Company: ....................................................................................................
Tel No: .................................................... Email: ..........................................................
Instalation Date: ..........................................................................................................
Engineers Name: .........................................................................................................
Engineers Signature: ...................................................................................................
WARRANTY
COM NO
L N
Live supply
230VAC 50Hz
}
Boiler Out
Live
Boiler In
COM NO
L N
Live supply
230VAC 50Hz
Live supply
230VAC 50Hz
*Remove the link (if applicable)
L
L N E
SL
}
L
L N E
SL
TECHNICAL DETAIL
INSTALLATION
Model
RX10RF
Type
Wired system receiver designed for
230VAC heating applications
Control
ON-OFF control
Environment Ratings
Operating Temperature
0 ºC to +50 ºC
Storage Temperature
-20 ºC to +60 ºC
Operating Humidity
5-95 %RH
Switch Voltage
0-230VAC 16AMP
Power Source
230Vac 50Hz
User Interface
Slide switch, Bi Colour LED, RED/GREEN
Operating Temperature
0 to 50 ºC
Storage Temperature
-20ºC to 60ºC
Frequency
2.4 GHz
Approval
CE
Terminal
Function
COM
Common Contact (volt free input)
NO
Normally Open Contact (volt free output)
Earth Parking
L
Incoming Mains - Live
N
Incoming Mains - Neutral
Wire up the receiver using
one of the schematics*.
Clip the front of the unit back on by aligning the
fittings and pushing into place.
Securely screw the front of the receiver in place.
4
5
1
2
3
4
5
6
Loosen the screws at the bottom of the receiver unit.
Unclip the front of the unit.
Fit the back of the receiver unit to the wall
using the fittings supplied.
1
2
3
Ensure Coordinator is powered
up and ready for pairing.
Power up the receiver.
The red light will flash.
When the receiver has successfully
joined the Zigbee network, the red
LED will go steady.
Please refer to VS10/VS20RF
manual for system pairing.
Once your system setup is complete,
remember to take the coordinator
out of pairing mode.
Reset Button
If for any reason the system receiver
stops operating, press reset and check
system operation.
*Configured
as RX2
*Configured
as RX1
Replacing the System Receiver
If for any reason the system receiver
needs to be removed/replaced, press the
delete from network.
Electrical Connection
Schematics
Power Up
The RX10RF Receiver should be mounted in a suitable location that is both accessible
for the connection of mains and control wiring, and allows good reception of the RF
signal. The Receiver needs a 230V AC mains supply to operate, and this should be
fused appropriately (16A max.).
The Receiver should be mounted in a location where it will not come into contact with
water, moisture or condensation. There are few electrical connections required to the
RX10RF, and these connections should be made to the terminal block inside the
Receiver. No Earth connection is required for the correct and safe operation of the
RX10RF, but a parking terminal is provided to connect an Earth wire if one is present.