background image

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

2

4

6

8

10

Introduction

Button functions

LCD Icon description

Technical specification

Product compliance

Safety Information

This product complies with the essential requirements and other relevant provisions of the following EU Directives: 

EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of 

Conformity is available on www.salus-controls.com/uk

RT510+ / / is a programmable room thermostat used to control room temperature. 

Device launching heating system by shorting terminal blocks, simultaneously informing the action and 

showing this information on the LCD display. Extended features allows us to use various operating modes 

- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual 

carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot 

located under the cover. Do not use rechargeable batteries.

Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. 

Product for indoor use only. Installation must be carried out by a qualified person in accordance to national 

and EU regulations.

RT510+ /  Thermostat

Receiver

1

6

7

8

9

4

3

2

5

1. 

Boost function

2. 

Manual Mode

3. 

Frost protection / Holiday Mode

4. 

Increase button

5. 

Decrease button

6. 

When in Manual Mode,  

 

ON will turn the boiler on.

7. 

When in Manual Mode,  

 

OFF will turn the boiler off.

8. 

Receiver operates in automatic mode   

 

according to the thermostat

9. 

Receiver output is controlled  

 

by the On/Off slide switch.

1. 

Day of the week

2. 

Program number

3. 

Program indicator

4. 

Settings

5. 

Temperature measured / set

6. 

Boost function

7.  

Low battery status

8. 

  Wireless connection with the receiver

9.

  Heating Mode On

10. 

  Manual Mode On

11.

   Holiday Mode On

12. 

Frost Protection Mode On

13. 

Temperature unit

14. 

AM / PM

15. 

Clock

RT510+ Thermostat

Thermostat

Thermostat supply

2 x AA alkaline batteries

2 x AA alkaline batteries

Thermostat rating max

3 (1) A

-

Outputs

Voltage free 

NO / COM / NC terminals

-

Temperature range

5 - 35°C

5 - 35°C

Temperature accuracy

0.1°C or 0.5°C

0.1°C or 0.5°C

Control algorithm

ITLC / SPAN 

ITLC / SPAN 

Radio frequency

-

868 MHz

Dimension [mm]

120x96x27

120x96x27

RXRT510 Receiver

Receiver supply

230 V AC

Receiver rating max

16 (5) A

Outputs

Voltage free NO / COM terminals

Radio frequency

868 MHz

Dimension [mm]

96x96x27

SALUS Controls plc
SALUS House
Dodworth Business Park South, 
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: [email protected]

E: [email protected]

SALUS Controls is a member of the 

Computime Group.

Maintaining a policy of continuous product 
development SALUS Controls plc reserve 
the right to change specification, design and 
materials of products listed in this brochure 
without prior notice.

RT510+, ,

& RT510RF (Thermostat) DIP Switch Settings

RT510+ Wiring diagram

L

RT510T

X+

Thermosta

t

RT510T

X+

Thermosta

t

N

M

CO

M

NO

NC

CO

M

NO

NC

OR

MAX

3 (1) A

AC 230 V

RT510+

Thermosta

t

RT510+

Thermosta

t

L

L

NO

N

N

COM

RXR

T510+

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

COM

L

L

M

N

N

NO

OR

A

230 V

MAX

16 (5) A

L

RT510T

X+

Thermosta

t

RT510T

X+

Thermosta

t

N

M

CO

M

NO

NC

CO

M

NO

NC

OR

MAX

3 (1) A

AC 230 V

RT510+

Thermosta

t

RT510+

Thermosta

t

L

L

NO

N

N

COM

RXR

T510+

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

COM

L

L

M

N

N

NO

OR

A

230 V

MAX

16 (5) A

Wiring diagram

Setting the time

Note: 

If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.

L

RT510T

X+

Thermosta

t

RT510T

X+

Thermosta

t

N

M

CO

M

NO

NC

CO

M

NO

NC

OR

MAX

3 (1) A

AC 230 V

RT510+

Thermosta

t

RT510+

Thermosta

t

L

L

NO

N

N

COM

RXR

T510+

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

COM

L

L

M

N

N

NO

OR

A

230 V

MAX

16 (5) A

L

RT510T

X+

Thermosta

t

RT510T

X+

Thermosta

t

N

M

CO

M

NO

NC

CO

M

NO

NC

OR

MAX

3 (1) A

AC 230 V

RT510+

Thermosta

t

RT510+

Thermosta

t

L

L

NO

N

N

COM

RXR

T510+

Rec

eiv

er

RXR

T510

Rec

eiv

er

A

230 V

COM

L

L

M

N

N

NO

OR

A

230 V

MAX

16 (5) A

RT510+ Terminals description

RXRT510 Receiver terminals description

Terminal

Description

1 - COM

Common Terminal

2 - NC

Switched Live OFF

3 - NO

Switched Live ON

Terminal

Description

NO

Switch Terminal

COM

Common Switch Terminal

L, N

Supply (230 V AC)

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

1

3

5

7

9

Press         or        to select the hour format.

Press the buttons SELECT and SET

together for 3 sec.

Press SELECT to confirm.

Press SELECT to confirm.

Press SELECT to confirm.

Press SET to confirm.

Press         or         to set the hour.

Press         or        to set the minutes.

Press        or        to set day of the week.

Thermostat will return to the main screen.

3 sec 3 sec

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

Programming - automatic mode

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

2

4

6

8

10

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

1

3

5

7

9

Use the         or         button to select day / days 

from which you want to start programming.

Use the         or         button to set the hour  

to start the program #1.

Use the         or        button to set the minutes  

to start the program #1.

Use the         or         button 

to set the temperature for program #1.

Follow steps 4-9,

to define programs 2-6.

Press SET button to end programming.

Press the SET button to start programming.

Press SELECT to confirm.

Press SELECT to confirm.

Press SELECT to confirm.

Press SELECT to confirm.

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of 

time). To do this, firstly choose programming mode: “5-2” (business days + weekend) or “24h” (each 

day separately) using parameter 

d04

 from 

Installer mode

. Programmed schedules should use all 

time periods.

ON

1

2

ON

ELEC SPAN

RAD

ITLC

The DIP Switches can be found on the rear of your thermostat.
For all plug-in boiler receiver applications ensure SW1 is set to RAD.

Control feature

ITLC

SPAN

Operation

When ITLC is selected on DIP 

switch № 2, the DIP switch № 

1 is functional. You can choose 

between radiator or electric 

heater.

When Span is selected 

on DIP switch № 2, the 

DIP switch № 1 is not 

functional. 

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

TEST / PAIRING

SELECT

SET

2

3

5

6

4

1

15

14

12

13

8

9

11

7

10

MON

TUE

WED

THU

FRI

SAT

SUN

MON

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

MON

TUE

WED

THU

FRI

THU

THU

THU

MON

MON

MON

MON

MON

www.salus-tech.com

Issue Date: July 2019

V033

For PDF Installation guide please go to

www.salus-manuals.com

Quick Guide

868.0-868.6MHz; <13dBm

Boiler

PLUS

COMPLIANT

Internal Temperature 

Load Compensation

ITLC

RT510+ (Thermostat) Dip Switch Settings

The DIP Switches can be found on the rear of your thermostat.

ON

1

2

ON

NA

SPAN

RAD

ITLC

Control feature

ITLC

SPAN

Operation

ITLC Internal Temperature 

Load Compensation for 

improved efficiency.

When Span is selected 

on DIP switch № 2, the 

DIP switch № 1 is not 

functional. 

Summary of Contents for RT510+

Page 1: ...RT510 RT510TX RT510RF Quick Guide Boiler PLUS COMPLIANT InternalTemperature Load Compensation ITLC ...

Page 2: ...se only AA 1 5V alkaline batteries in the thermostat Place the batteries into the battery slot located under the cover Do not use rechargeable batteries Use in accordance to national and EU regulations Use the device as intended keeping it in dry condition Product for indoor use only Installation must be carried out by a qualified person in accordance to national andEUregulations RT510 Thermostat ...

Page 3: ... N COM RXRT510 Receiver AC 230 V RT510 Terminals description RXRT510 Receiver terminals description Terminal Description 1 COM CommonTerminal 2 NC Switched Live OFF 3 NO Switched Live ON Terminal Description NO SwitchTerminal COM Common SwitchTerminal L N Supply 230V AC ON 1 2 ON ELEC SPAN RAD ITLC TheDIPSwitchescanbefoundontherearofyourthermostat Forallplug inboilerreceiverapplicationsensureSW1is...

Page 4: ... Thermostat L L NO N N COM RXRT510 Receiver AC 230 V RT510TX Thermostat M OR MAX 3 1 A RXRT510 Receiver COM L L M N N NO OR AC 230 V MAX 16 5 A TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET 1 3 5 Press or to select the hour format Press the buttons SELECT and SET together for 3 sec Press SELECT to confirm Press SELECT to confirm Press or to set the hour Press or to set th...

Page 5: ...rogramming Press the SET button to start programming Press SELECT to confirm Press SELECT to confirm Press SELECT to confirm Press SELECT to confirm TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET TEST PAIRING SELECT SET In this mode user can set the schedules for thermostat temp...

Page 6: ...IRING TEST PAIRING SELECT SET TEST PAIRING TEST PAIRING This function is available only in automatic mode schedule If a new setpoint temperature will be set during the schedule it will be maintained until next time interval starts according to programmed schedule In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature This function is av...

Page 7: ... frost protection temperature is maintained for a specific number of days Turning Off the Frost Protection Mode ToturnofftheHolidayMode holddown buttonfor3seconds Theairplaneicon should disappearfromthedisplay Temperature of the Frost Protection mode is set as default at 5 C This temperature can be changed inInstallerModeind03parameter Whenthesleepmodeisactivated allthermostatfunctionsarepaused 2 ...

Page 8: ...ouareusingtheRT510RF pack thepairingbetweenthethermostatandthereceiverisalreadydone TEST PAIRING SELECT SET PressTEST PAIRINGbuttontocheckthe connectionwiththereceiver ON AUTO OFF MANUAL 1 sec TEST PAIRING SELECT SET TEST PAIRING SELECT SET the pairing process takes up to 9 minutes Press and holdTEST PAIRING button for 3 seconds 3 sec TEST PAIRING SELECT SET THU TEST PAIRING SELECT SET TEST PAIRIN...

Page 9: ...e will use the internal memory to backup your settings You have 30 seconds to change the batteries before losing your settings Press the RESET button once You can use a paper clip Your thermostat will be reset and will start up automatically Removethebatterieswithoutpressinganybutton Wait2minutesandinsertthebatteriesagain Yourdevicewillberestarted 3 sec 3 sec 3 sec dxx Function Parameter Default v...

Page 10: ...us tech com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice www salus tech com Issue Date July 2019 V033 For PDF Installation guide please go to www salus manuals com ...

Reviews: